What are you looking for?

Enter search term

We are sorry!

Unfortunately no results were found.

Christmas / New Year shipping times
Our central warehouses will be closed from 23.12.2024 to 01.01.2025. Incoming orders will not be shipped during this period. If necessary, you are welcome to use our branch network during this time. Customer service will be available as usual.

Login

Sie sind Neukunde?

Registrieren Sie sich und sichern Sie sich viele Vorteile:

Prüfung der Produktverfügbarkeit
Schnelle Nachbestellung & Bestellhistorie
Persönliche Produktempfehlungen
Zahlung per Rechnung

Help & Contact

Ihr direkter Draht zu uns

Bei Fragen zum Online-Shop oder zu unseren Produkten erreichen Sie unseren Kundenservice unter:

Monday - Thursday: 8:00AM - 5:00PM
Friday: 8:00AM - 4:00PM
Except saturdays, sundays and holidays

Oder nutzen Sie unser FAQ

Hier erhalten Sie Antworten auf die am häufigsten
gestellten Fragen.

Helping people help themselves
FAQs

K- 07 50 00 36

Digitaler Durchflussschalter
Consommation d'électricité maxi
150 mA
Filet de raccord
G 2″ -11 
Signal de sortie
PNP + Analog output (1-5V) 
Download PDF
Product details for

K- 07 50 00 36

Consommation d'électricité maxi
150 mA
Filet de raccord
G 2″ -11
Signal de sortie
PNP + Analog output (1-5V)
Tension nominale / type de courant
24 Vcc
Adjustment unit min.
10 l/min
Measuring range
600 to 12000 l/min
Min. working pressure
1.5 MPa
All characteristics

Characteristics

Tension nominale
  • 24 V DC 
Câble E/S
  • without connection cable 
Indice de protection
  • IP 65 
Température ambiante
  • 0 °C to +50 °C 
Température de fluide
  • 0 °C to +50 °C 
Série
  • PF2A 
Construction
  • Interrupteur de flux numérique 
Médiums
  • air and nitrogen 
Pression de service maxi
  • 0,1 MPa 
Précision de répétition
  • max. ±3 % from scale 
Customs tariff number
  • 90261021 
All characteristics

Produktbeschreibung

Description
Digital flow switch for high flow, series PF2A, for air and nitrogen, with integrated display unit, measuring range 150 to 3000 l/min, smallest adjustment unit 5 l/min, media temperature 0 to 50 °C, operating temperature range 0 to 50 °C, repetition accuracy max. ±3% of the measuring range, temperature characteristic max. ±2% of the measuring range. (0 to 50 °C, based on 25 °C), current consumption max. 150 mA, measuring principle thermistor (heating element), operating display 3-digit, 7-segment LED (lights up when output signal ON OUT1: Green;OUT2: Red), operating pressure range 0.1 to 1.5 MPa, switch output PNP open collector 1 output and 1 analogue output (1 to 5 V), with function to switch over the display unit, supply voltage 24 V DC, protection class IP 65, connection cable not included, connection size G 1 1/2
Further information
For high flow
Integrated Display Type

Product variants

6 Results
Identifier
Adjustment unit min. (l/min)
Connecting thread
Max. current consumption (mA)
Nominal voltage/ current type
Details / items
5 l/min
G 1″ -11 
150 mA
24 V DC 
Learn more
5 l/min
G 1″ -11 
150 mA
Learn more
10 l/min
G 1.1/2″ -11 
150 mA
24 V DC 
Learn more
10 l/min
G 1.1/2″ -11 
150 mA
Learn more
10 l/min
G 2″ -11 
150 mA
24 V DC 
Learn more
10 l/min
G 2″ -11 
150 mA
Learn more

Column selection

Adjustment unit min. (l/min)
Connecting thread
Max. current consumption (mA)
Nominal voltage/ current type
Output signal
Measuring range
Min. working pressure (MPa)