AOVR O

Screw-in fitting



Properties

Connection 1 BSP external thread, cylindrical
Connection 2 metric nut thread
Design Screw-in fitting
Construction straight
Sealing form 1 form G
Sealing form 2 24° outer cone with O-ring
Surface electro galvanised
Material Steel

Hints

Information about fitting, installation, pressure loads and permissible operating temperatures can be found in the technical information for pipe fittings.

Article Table

Product Name Series Operating pressure Ø d mm G1 G2 i mm L2 mm AF mm S1 OR1 OR2
Product Name Series Operating pressure Ø d mm G1 G2 i mm L2 mm AF mm S1 OR1 OR2
AOVR O NW 03 S S PN 630 6 G 1/4" -19 M 14 x 1.5 12 26,0 19 17 9.30 x 2.30 4.0 x 1.5
AOVR O NW 04 S S PN 630 8 G 1/4" -19 M 16 x 1.5 12 28,0 19 19 11.30 x 2.30 6.0 x 1.5
AOVR O NW 06 S S PN 630 10 G 3/8" -19 M 18 x 1.5 12 30,5 22 22 13.30 x 2.30 7.5 x 1.5
AOVR O NW 08 S S PN 630 12 G 3/8" -19 M 20 x 1.5 12 32,5 22 24 15.30 x 2.30 9.0 x 1.5
AOVR O NW 10 S S PN 630 14 G 1/2" -14 M 22 x 1.5 14 36,0 27 27 17.86 x 2.62 10.0 x 2.0
AOVR O NW 13 S S PN 400 16 G 1/2" -14 M 24 x 1.5 14 36,5 27 30 12.00 x 2.00 12.0 x 2.0
AOVR O NW 16 S S PN 400 20 G 3/4" -14 M 30 x 2 16 40,5 32 36 23.50 x 3.00 16.3 x 2.4
AOVR O NW 20 S S PN 400 25 G 1" -11 M 36 x 2 18 46,0 41 46 29.50 x 3.00 20.3 x 2.4
AOVR O NW 25 S S PN 250 30 G 1.1/4" -11 M 42 x 2 20 48,0 50 50 38.00 x 3.00 25.3 x 2.4
AOVR O NW 32 S S PN 250 38 G 1.1/2" -11 M 52 x 2 22 55,0 55 55 44.04 x 3.53 33.3 x 2.4
Series: LL = Very light L = Light S = Heavy - PN = Nominal pressure PB = Max. operating pressure - Ø d = External pipe diameter

Disclaimer

Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.