Product Name Series Operating pressure Ø d2 mm G1 G2 i mm L2 mm AF mm S1
Product Name Series Operating pressure Ø d2 mm G1 G2 i mm L2 mm AF mm S1
AVN NW 04 L L PN 315 6 1/8" -27 NPT M 12 x 1.5 9,9 23,1 11 14
AVN NW 06 L L PN 315 8 1/4" -18 NPT M 14 x 1.5 15,1 23,9 14 17
AVN NW 08 L L PN 315 10 1/4" -18 NPT M 16 x 1.5 15,1 25,4 17 19
AVN NW 10 L L PN 315 12 3/8" -18 NPT M 18 x 1.5 15,2 26,2 19 22
AVN NW 13 L L PN 315 15 1/2" -14 NPT M 22 x 1.5 19,8 28,2 22 27
AVN NW 16 L L PN 315 18 1/2" -14 NPT M 26 x 1.5 20,1 28,7 27 32
AVN NW 20 L L PN 160 22 3/4" -14 NPT M 30 x 2 25,0 28,9 27 36
AVN NW 25 L L PN 160 28 1" -11.5 NPT M 36 x 2 25,6 30,5 36 41
AVN NW 32 L L PN 160 35 1.1/4" -11.5 NPT M 45 x 2 26,0 37,4 46 50
AVN NW 40 L L PN 160 42 1.1/2" -11.5 NPT M 52 x 2 15,1 39,0 50 60
AVN NW 03 S S PN 630 6 1/4" -18 NPT M 14 x 1.5 15,1 24,9 14 17
AVN NW 04 S S PN 630 8 1/4" -18 NPT M 16 x 1.5 15,2 24,9 14 19
AVN NW 06 S S PN 630 10 3/8" -18 NPT M 18 x 1.5 15,2 29,3 19 22
AVN NW 08 S S PN 630 12 3/8" -18 NPT M 20 x 1.5 19,8 28,3 19 24
AVN NW 10 S S PN 630 14 1/2" -14 NPT M 22 x 1.5 19,8 33,2 22 27
AVN NW 13 S S PN 400 16 1/2" -14 NPT M 24 x 1.5 20,1 33,7 22 30
AVN NW 16 S S PN 400 20 3/4" -14 NPT M 30 x 2 25,0 37,9 27 36
AVN NW 20 S S PN 400 25 1" -11.5 NPT M 36 x 1.5 25,0 43,5 36 46
AVN NW 25 S S PN 400 30 1.1/4" -11.5 NPT M 42 x 2 25,6 47,9 46 50
AVN NW 32 S S PN 315 38 1.1/2" -11.5 NPT M 52 x 2 26,0 52,0 50 60
Series: LL = Very light L = Light S = Heavy - PN = Nominal pressure PB = Max. operating pressure - Ø d2 = External pipe diameter

Disclaimer

Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.