FI MD 315

Medium pressure filter 315 bar

  • Image_1 Image_1
  • Image_2 Image_2
  • Image_3 Image_3

Properties

Design without bypass valve, without clogging indicator
Material Filter head of GGG
Scope of supply incl. filter element
Temp. max. 120 °C
Temp. min. -10 °C

Description

Pressure filter for pipeline installation
Pressure differential for filter element inorganic (A) max. 210 bar
Connector for clogging indicator M20 x 1.5 sealed with bolt

Hints

Dimension “L”: clearance required for changing the filter element

Article Table

Product Name L1 mm L2 mm L mm Operating pressure bar AF mm G1 Ø A mm Filter area cm² Volumetric flow max. l/min Filter mesh size µm Ø B mm Weight kg
Product Name L1 mm L2 mm L mm Operating pressure bar AF mm G1 Ø A mm Filter area cm² Volumetric flow max. l/min Filter mesh size µm Ø B mm Weight kg
FI MD 040 A06 N 001 G12 189.0 31.0 80.0 315 27 G 1/2" 92.0 425 40 6.0 66.0 3.900
FI MD 050 A10V N 010 189.0 31.0 80.0 315 27 G 1/2" 92.0 425 50 10.0 66.0 4.100
FI MD 060 A06 N 001 G34 267.0 31.0 80.0 315 27 G 3/4" 92.0 850 60 6.0 66.0 4.200
FI MD 080 A10V N 010 267.0 31.0 80.0 315 27 G 3/4" 92.0 850 75 10.0 66.0 5.150
FI MD 080 A06 N 001 G34 343.0 31.0 80.0 315 27 G 3/4" 92.0 1275 80 6.0 66.0 5.700
FI MD 090 A10 N 001 G34 343.0 31.0 80.0 315 27 G 3/4" 92.0 1275 90 10.0 66.0 5.700
FI MD 170 A06 N 001 G114 257.0 32.0 110.0 210 30 G 1.1/4" 142.0 2010 170 6.0 109.0 9.400
FI MD 190 A10 N 001 G114 257.0 32.0 110.0 210 30 G 1.1/4" 142.0 2010 190 10.0 109.0 9.400
FI MD 240 A06 N 001 G114 371.0 32.0 110.0 210 30 G 1.1/4" 142.0 3800 240 6.0 109.0 16.500
FI MD 260 A10 N 001 G114 371.0 32.0 110.0 210 30 G 1.1/4" 142.0 3800 260 10.0 109.0 16.500
Qmax - max intake volumetric flow
A10 with inorganic filter (10 µm), absolute filtration
P10 paper filter (10 µm), nominal filtration
BD = Working pressure

Disclaimer

Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.