FI MD GEH

High pressure filter 400bar

  • Image_1 Image_1
  • Image_2 Image_2

Properties

Design without bypass valve, without clogging indicator
Lieferumfang without filter element
Material Filter head of GGG
Max. operating pressure up to 315 bar
Online-Shop https://shop.hansa-flex.com/de/FIMDGEH
Temp. max. 120 °C
Temp. min. -10 °C

Description

Pressure filter for pipeline installation
Connector for clogging indicator M20 x 1.5 sealed with bolt

Hints

Maß "L": benötigter Freiraum zum Wechseln des Filterelementes

Article Table

Product Name L1 mm L2 mm Ø A mm BD nom. bar für Filtertyp SW mm Ø B mm G1 Gewicht kg L mm
Product Name L1 mm L2 mm Ø A mm BD nom. bar für Filtertyp SW mm Ø B mm G1 Gewicht kg L mm
FIMDGEHN040050G12 189.0 mm 31.0 mm 92.0 mm 315 bar FI MD 040, 050 27 mm 66.0 mm G 1/2" 3.60 kg 80.0 mm
FIMDGEHN060075G34 267.0 mm 31.0 mm 92.0 mm 315 bar FI MD 060, 080 27 mm 66.0 mm G 3/4" 3.90 kg 80.0 mm
FIMDGEHN080090G34 343.0 mm 31.0 mm 92.0 mm 315 bar FI MD 080, 090 27 mm 66.0 mm G 3/4" 5.10 kg 80.0 mm
FIMDGEHN170190G114 257.0 mm 32.0 mm 142.0 mm 210 bar FI MD 170, 190 27 mm 109.0 mm G 1.1/4" 8.50 kg 110.0 mm
FIMDGEHN240260G114 371.0 mm 32.0 mm 142.0 mm 210 bar FI MD 240, 260 30 mm 109.0 mm G 1.1/4" 15.30 kg 110.0 mm
BD = Working pressure

Order hints

Filterelement ist nicht enthalten! Bitte separat bestellen.

Disclaimer

Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.