HK DG4V5

Solenoid-operated directional control valve NG10

Properties

Connection ISO/Cetop 05 size 10
Design 4/2-way valve or 4/3-way valve
with manual emergency operation
Max. operating pressure P, A, B: max. 315 bar / T: max. 160 bar (VDC) / T: max. 120 bar (VAC)
Mounting 4 pcs. socket head screw M6x40 12.9
Scope of supply with coil, without plug
Volumetric flow max. 120 l/min (note characteristic curves)
protection class IP 65

Description

switching capacity limits see characteristic curves

Hints

The O-rings (NBR 70° Shore A) for the valve port can be ordered as spare part separately under the following article number: 5 pieces OR12.42-1.78

Article Table

Product Name Overlap Type Rated voltage/brcurrent type Piston type Weight kg Version
Product Name Overlap Type Rated voltage/brcurrent type Piston type Weight kg Version
HK DG4V5 0BJ VM U 12DC negative (open) 4/2 12 VDC 0BJ [PB/AT]-[ABPT] 3.60 Spring return
HK DG4V5 0BJ VM U 24DC negative (open) 4/2 24 VDC 0BJ [PB/AT]-[ABPT] 3.60 Spring return
HK DG4V5 0B VM U 110AC negative (open) 4/2 110 VAC 0B [PB/AT]-[ABPT] 3.60 Spring return
HK DG4V5 0B VM U 230AC negative (open) 4/2 230 VAC 50 Hz 0B [PB/AT]-[ABPT] 3.60 Spring return
HK DG4V5 2AJ VM U 12DC positive (closed) 4/2 12 VDC 2AJ [PB/AT]-[PA/BT] 3.60 Spring return
HK DG4V5 2AJ VM U 24DC positive (closed) 4/2 24 VDC 2AJ [PB/AT]-[PA/BT] 3.60 Spring return
HK DG4V5 2A VM U 110AC positive (closed) 4/2 110 VAC 2A [PB/AT]-[PA/BT] 3.60 Spring return
HK DG4V5 2A VM U 230AC positive (closed) 4/2 230 VAC 50 Hz 2A [PB/AT]-[PA/BT] 3.60 Spring return
HK DG4V5 2ALJ VM U 12DC positive (closed) 4/2 12 VDC 2ALJ [PB/AT]-[PA/BT] 3.60 Spring return
HK DG4V5 2ALJ VM U 24DC positive (closed) 4/2 24 VDC 2ALJ [PB/AT]-[PA/BT] 3.60 Spring return
HK DG4V5 2AL VM U 110AC positive (closed) 4/2 110 VAC 2AL [PB/AT]-[PA/BT] 3.60 Spring return
HK DG4V5 2AL VM U 230AC positive (closed) 4/2 230 VAC 50 Hz 2AL [PB/AT]-[PA/BT] 3.60 Spring return
HK DG4V5 2BJ VM U 12DC positive (closed) 4/2 12 VDC 2BJ [PB/AT]-[A/B/P/T] 3.60 Spring return
HK DG4V5 2BJ VM U 24DC positive (closed) 4/2 24 VDC 2BJ [PB/AT]-[A/B/P/T] 3.60 Spring return
HK DG4V5 2B VM U 110AC positive (closed) 4/2 110 VAC 2B [PB/AT]-[A/B/P/T] 3.60 Spring return
HK DG4V5 2B VM U 230AC positive (closed) 4/2 230 VAC 50 Hz 2B [PB/AT]-[A/B/P/T] 3.60 Spring return
HK DG4V5 6BJ VM U 12DC positive (closed) 4/2 12 VDC 6BJ [PB/AT]-[ABT/P] 3.60 Spring return
HK DG4V5 6BJ VM U 24DC positive (closed) 4/2 24 VDC 6BJ [PB/AT]-[ABT/P] 3.60 Spring return
HK DG4V5 6B VM U 110AC positive (closed) 4/2 110 VAC 6B [PB/AT]-[ABT/P] 3.60 Spring return
HK DG4V5 6B VM U 230AC positive (closed) 4/2 230 VAC 50 Hz 6B [PB/AT]-[ABT/P] 3.60 Spring return
HK DG4V5 22AJ VM U 12DC positive (closed) 4/2 12 VDC 22AJ [PB/A/T]-[PA/B/T] 3.60 Spring return
HK DG4V5 22AJ VM U 24DC positive (closed) 4/2 24 VDC 22AJ [PB/A/T]-[PA/B/T] 3.60 Spring return
HK DG4V5 22A VM U 110AC positive (closed) 4/2 110 VAC 22A [PB/A/T]-[PA/B/T] 3.60 Spring return
HK DG4V5 22A VM U 230AC positive (closed) 4/2 230 VAC 50 Hz 22A [PB/A/T]-[PA/B/T] 3.60 Spring return
HK DG4V5 0CJ VM U 12DC negative (open) 4/3 12 VDC 0CJ [PB/AT]-[ABPT]-[PA/BT] 4.30 spring return to 0
HK DG4V5 0CJ VM U 24DC negative (open) 4/3 24 VDC 0CJ [PB/AT]-[ABPT]-[PA/BT] 4.30 spring return to 0
HK DG4V5 0C VM U 110AC negative (open) 4/3 110 VAC 0C [PB/AT]-[ABPT]-[PA/BT] 4.30 spring return to 0
HK DG4V5 0C VM U 230AC negative (open) 4/3 230 VAC 50 Hz 0C [PB/AT]-[ABPT]-[PA/BT] 4.30 spring return to 0
HK DG4V5 2CJ VM U 12DC positive (closed) 4/3 12 VDC 2CJ [PB/AT]-[A/B/P/T]-[PA/BT] 4.30 spring return to 0
HK DG4V5 2CJ VM U 24DC positive (closed) 4/3 24 VDC 2CJ [PB/AT]-[A/B/P/T]-[PA/BT] 4.30 spring return to 0
HK DG4V5 2C VM U 110AC positive (closed) 4/3 110 VAC 2C [PB/AT]-[A/B/P/T]-[PA/BT] 4.30 spring return to 0
HK DG4V5 2C VM U 230AC positive (closed) 4/3 230 VAC 50 Hz 2C [PB/AT]-[A/B/P/T]-[PA/BT] 4.30 spring return to 0
HK DG4V5 6CJ VM U 12DC positive (closed) 4/3 12 VDC 6CJ [PB/AT]-[ABT/P]-[PA/BT] 4.30 spring return to 0
HK DG4V5 6CJ VM U 24DC positive (closed) 4/3 24 VDC 6CJ [PB/AT]-[ABT/P]-[PA/BT] 4.30 spring return to 0
HK DG4V5 6C VM U 110AC positive (closed) 4/3 110 VAC 6C [PB/AT]-[ABT/P]-[PA/BT] 4.30 spring return to 0
HK DG4V5 6C VM U 230AC positive (closed) 4/3 230 VAC 50 Hz 6C [PB/AT]-[ABT/P]-[PA/BT] 4.30 spring return to 0
HK DG4V5 8CJ VM U 12DC negative (open) 4/3 12 VDC 8CJ [PA/BT]-[A/B/PT]-[PB/AT] 4.30 spring return to 0
HK DG4V5 8CJ VM U 24DC negative (open) 4/3 24 VDC 8CJ [PA/BT]-[A/B/PT]-[PB/AT] 4.30 spring return to 0
HK DG4V5 8CJ VM U 110AC negative (open) 4/3 110 VAC 8CJ [PA/BT]-[A/B/PT]-[PB/AT] 4.30 spring return to 0
HK DG4V5 8CJ VM U 230AC negative (open) 4/3 230 VAC 50 Hz 8CJ [PA/BT]-[A/B/PT]-[PB/AT] 4.30 spring return to 0
HK DG4V5 2NJ VM U 12DC positive (closed) 4/3 12 VDC 2NJ [PB/AT]-[PA/BT] 4.30 2 latching positions
HK DG4V5 2NJ VM U 24DC positive (closed) 4/3 24 VDC 2NJ [PB/AT]-[PA/BT] 4.30 2 latching positions
HK DG4V5 2N VM U 110AC positive (closed) 4/3 110 VAC 2N [PB/AT]-[PA/BT] 4.30 2 latching positions
HK DG4V5 2N VM U 230AC positive (closed) 4/3 230 VAC 50 Hz 2N [PB/AT]-[PA/BT] 4.30 2 latching positions
Piston type example: [A/B/PT] = [A blocked / B blocked / P+T connected]

Order hints

Further circuits and versions, volumetric flows and switching power limits on request

Disclaimer

Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.