HK DG4V5

Solenoid-operated directional control valve NG10

Properties

Connection ISO/Cetop 05 size 10
Design 4/2-way valve or 4/3-way valve
with manual emergency operation
Max. operating pressure P, A, B: max. 315 bar / T: max. 160 bar (VDC) / T: max. 120 bar (VAC)
Mounting 4 pcs. socket head screw M6x40 12.9
Scope of supply with coil, without plug
Volumetric flow max. 120 l/min (note characteristic curves)
protection class IP 65

Description

switching capacity limits see characteristic curves

Hints

The O-rings (NBR 70° Shore A) for the valve port can be ordered as spare part separately under the following article number: 5 pieces OR12.42-1.78

Article Table

Product Name Type Overlap Piston type Rated voltage/brcurrent type Version Weight kg
Product Name Type Overlap Piston type Rated voltage/brcurrent type Version Weight kg
HK DG4V5 0BJ VM U 12DC 4/2 negative (open) 0BJ [PB/AT]-[ABPT] 12 VDC Spring return 3.600
HK DG4V5 0BJ VM U 24DC 4/2 negative (open) 0BJ [PB/AT]-[ABPT] 24 VDC Spring return 3.600
HK DG4V5 0B VM U 110AC 4/2 negative (open) 0B [PB/AT]-[ABPT] 110 VAC Spring return 3.600
HK DG4V5 0B VM U 230AC 4/2 negative (open) 0B [PB/AT]-[ABPT] 230 VAC 50 Hz Spring return 3.600
HK DG4V5 2AJ VM U 12DC 4/2 positive (closed) 2AJ [PB/AT]-[PA/BT] 12 VDC Spring return 3.600
HK DG4V5 2AJ VM U 24DC 4/2 positive (closed) 2AJ [PB/AT]-[PA/BT] 24 VDC Spring return 3.600
HK DG4V5 2A VM U 110AC 4/2 positive (closed) 2A [PB/AT]-[PA/BT] 110 VAC Spring return 3.600
HK DG4V5 2A VM U 230AC 4/2 positive (closed) 2A [PB/AT]-[PA/BT] 230 VAC 50 Hz Spring return 3.600
HK DG4V5 2ALJ VM U 12DC 4/2 positive (closed) 2ALJ [PB/AT]-[PA/BT] 12 VDC Spring return 3.600
HK DG4V5 2ALJ VM U 24DC 4/2 positive (closed) 2ALJ [PB/AT]-[PA/BT] 24 VDC Spring return 3.600
HK DG4V5 2AL VM U 110AC 4/2 positive (closed) 2AL [PB/AT]-[PA/BT] 110 VAC Spring return 3.600
HK DG4V5 2AL VM U 230AC 4/2 positive (closed) 2AL [PB/AT]-[PA/BT] 230 VAC 50 Hz Spring return 3.600
HK DG4V5 2BJ VM U 12DC 4/2 positive (closed) 2BJ [PB/AT]-[A/B/P/T] 12 VDC Spring return 3.600
HK DG4V5 2BJ VM U 24DC 4/2 positive (closed) 2BJ [PB/AT]-[A/B/P/T] 24 VDC Spring return 3.600
HK DG4V5 2B VM U 110AC 4/2 positive (closed) 2B [PB/AT]-[A/B/P/T] 110 VAC Spring return 3.600
HK DG4V5 2B VM U 230AC 4/2 positive (closed) 2B [PB/AT]-[A/B/P/T] 230 VAC 50 Hz Spring return 3.600
HK DG4V5 6BJ VM U 12DC 4/2 positive (closed) 6BJ [PB/AT]-[ABT/P] 12 VDC Spring return 3.600
HK DG4V5 6BJ VM U 24DC 4/2 positive (closed) 6BJ [PB/AT]-[ABT/P] 24 VDC Spring return 3.600
HK DG4V5 6B VM U 110AC 4/2 positive (closed) 6B [PB/AT]-[ABT/P] 110 VAC Spring return 3.600
HK DG4V5 6B VM U 230AC 4/2 positive (closed) 6B [PB/AT]-[ABT/P] 230 VAC 50 Hz Spring return 3.600
HK DG4V5 22AJ VM U 12DC 4/2 positive (closed) 22AJ [PB/A/T]-[PA/B/T] 12 VDC Spring return 3.600
HK DG4V5 22AJ VM U 24DC 4/2 positive (closed) 22AJ [PB/A/T]-[PA/B/T] 24 VDC Spring return 3.600
HK DG4V5 22A VM U 110AC 4/2 positive (closed) 22A [PB/A/T]-[PA/B/T] 110 VAC Spring return 3.600
HK DG4V5 22A VM U 230AC 4/2 positive (closed) 22A [PB/A/T]-[PA/B/T] 230 VAC 50 Hz Spring return 3.600
HK DG4V5 0CJ VM U 12DC 4/3 negative (open) 0CJ [PB/AT]-[ABPT]-[PA/BT] 12 VDC spring return to 0 4.300
HK DG4V5 0CJ VM U 24DC 4/3 negative (open) 0CJ [PB/AT]-[ABPT]-[PA/BT] 24 VDC spring return to 0 4.300
HK DG4V5 0C VM U 110AC 4/3 negative (open) 0C [PB/AT]-[ABPT]-[PA/BT] 110 VAC spring return to 0 4.300
HK DG4V5 0C VM U 230AC 4/3 negative (open) 0C [PB/AT]-[ABPT]-[PA/BT] 230 VAC 50 Hz spring return to 0 4.300
HK DG4V5 2CJ VM U 12DC 4/3 positive (closed) 2CJ [PB/AT]-[A/B/P/T]-[PA/BT] 12 VDC spring return to 0 4.300
HK DG4V5 2CJ VM U 24DC 4/3 positive (closed) 2CJ [PB/AT]-[A/B/P/T]-[PA/BT] 24 VDC spring return to 0 4.300
HK DG4V5 2C VM U 110AC 4/3 positive (closed) 2C [PB/AT]-[A/B/P/T]-[PA/BT] 110 VAC spring return to 0 4.300
HK DG4V5 2C VM U 230AC 4/3 positive (closed) 2C [PB/AT]-[A/B/P/T]-[PA/BT] 230 VAC 50 Hz spring return to 0 4.300
HK DG4V5 6CJ VM U 12DC 4/3 positive (closed) 6CJ [PB/AT]-[ABT/P]-[PA/BT] 12 VDC spring return to 0 4.300
HK DG4V5 6CJ VM U 24DC 4/3 positive (closed) 6CJ [PB/AT]-[ABT/P]-[PA/BT] 24 VDC spring return to 0 4.300
HK DG4V5 6C VM U 110AC 4/3 positive (closed) 6C [PB/AT]-[ABT/P]-[PA/BT] 110 VAC spring return to 0 4.300
HK DG4V5 6C VM U 230AC 4/3 positive (closed) 6C [PB/AT]-[ABT/P]-[PA/BT] 230 VAC 50 Hz spring return to 0 4.300
HK DG4V5 8CJ VM U 12DC 4/3 negative (open) 8CJ [PA/BT]-[A/B/PT]-[PB/AT] 12 VDC spring return to 0 4.300
HK DG4V5 8CJ VM U 24DC 4/3 negative (open) 8CJ [PA/BT]-[A/B/PT]-[PB/AT] 24 VDC spring return to 0 4.300
HK DG4V5 8CJ VM U 110AC 4/3 negative (open) 8CJ [PA/BT]-[A/B/PT]-[PB/AT] 110 VAC spring return to 0 4.300
HK DG4V5 8CJ VM U 230AC 4/3 negative (open) 8CJ [PA/BT]-[A/B/PT]-[PB/AT] 230 VAC 50 Hz spring return to 0 4.300
HK DG4V5 2NJ VM U 12DC 4/3 positive (closed) 2NJ [PB/AT]-[PA/BT] 12 VDC 2 latching positions 4.300
HK DG4V5 2NJ VM U 24DC 4/3 positive (closed) 2NJ [PB/AT]-[PA/BT] 24 VDC 2 latching positions 4.300
HK DG4V5 2N VM U 110AC 4/3 positive (closed) 2N [PB/AT]-[PA/BT] 110 VAC 2 latching positions 4.300
HK DG4V5 2N VM U 230AC 4/3 positive (closed) 2N [PB/AT]-[PA/BT] 230 VAC 50 Hz 2 latching positions 4.300
Piston type example: [A/B/PT] = [A blocked / B blocked / P+T connected]

Order hints

Further circuits and versions, volumetric flows and switching power limits on request

Disclaimer

Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.