HK DHE X 00 AC

Solenoid-operated directional control valve size 6 without coil



Properties

Connection ISO/Cetop 03 size 6
Design 3-chamber valve, 4/2-way valve or 4/3-way valve, for AC coils, with manual emergency operation
Mounting 4 pcs. socket head screw M5x30 12.9
Scope of supply without coil or plug
Operating pressure P, A, B: max. 350bar / T: max. 160bar
Volumetric flow max. 80 l/min (note characteristic curves)

Description

Can only be used for AC coils
switching capacity limits see characteristic curves

Hints

Valves marked with (P) are leak oil reduced valves. With flow quantities of >70 % of the nominal values here, an increased drop in pressure is to be expected.
Leak oil reduced valves are also used as pilot valves for pilot-controlled solenoid-operated directional control valves.
When using a leak oil-reduced valve type HK DH* 0711 P *** as a pilot valve, the centre position of the main valve is overridden.

Article Table

Product Name Type Overlap Piston type Design Weight kg
Product Name Type Overlap Piston type Design Weight kg
HK DHE 0610 X 00AC 4/2 negative (open) 0 [PB/AT]-[ABPT] Spring return 1,35
HK DHE 0611 X 00AC 4/2 positive (closed) 1 [PB/AT]-[A/B/P/T] Spring return 1,35
HK DHE 0613 X 00AC 4/2 positive (closed) 3 [PB/AT]-[ABT/P] Spring return 1,35
HK DHE 0614 X 00AC 4/2 negative (open) 4 [PA/BT]-[A/B/PT] Spring return 1,35
HK DHE 0630 2 X 00AC 4/2 negative (open) 0/2 [PB/AT]-[PA/BT] Spring return 1,35
HK DHE 0631 2A 00AC 4/2 positive (closed) 1/2 [PB/AT]-[PA/BT] Spring return 1,35
HK DHE 0631 2 X 00AC 4/2 positive (closed) 1/2 [PB/AT]-[PA/BT] Spring return 1,35
HK DHE 0632 2 X 00AC 4/2 positive (closed) 2/2 [PB/A/T]-[PA/B/T] Spring return 1,35
HK DHE 0710 X 00AC 4/3 negative (open) 0 [PB/AT]-[ABPT]-[PA/BT] spring return to 0 1,75
HK DHE 0710 9 X 00AC 4/3 negative (open) 09 [PB/AT]-[ABPT]-[PAB/T] spring return to 0 1,75
HK DHE 0711 X 00AC 4/3 positive (closed) 1 [PB/AT]-[A/B/P/T]-[PA/BT] spring return to 0 1,75
HK DHE 0713 X 00AC 4/3 positive (closed) 3 [PB/AT]-[ABT/P]-[PA/BT] spring return to 0 1,75
HK DHE 0714 X 00AC 4/3 negative (open) 4 [PA/BT]-[A/B/PT]-[PB/AT] spring return to 0 1,75
HK DHE 0714 9 X 00AC 4/3 positive (closed) 49 [PA/BT]-[A/B/PT]-[PAB/T] spring return to 0 1,75
HK DHE 0716 X 00AC 4/3 positive (closed) 6 [PB/AT]-[AT/P/B]-[PA/BT] spring return to 0 1,75
HK DHE 0717 X 00AC 4/3 positive (closed) 7 [PB/AT]-[A/P/BT]-[PA/BT] spring return to 0 1,75
HK DHE 0718 X 00AC 4/3 positive (closed) 8 [PB/AT]-[PAB/T]-[PA/BT] spring return to 0 1,75
HK DHE 0719 1 X 00AC 4/3 positive (closed) 91 [PAB/T]-[A/B/P/T]-[PA/BT] spring return to 0 1,75
HK DHE 0751 2 X 00AC 4/2 positive (closed) 1/2 [PB/AT]-[PA/BT] 2 latching positions 1,75
HK DHE 0711 P X 00AC 4/3 positive (closed) 1 [PB/AT]-[A/B/P/T]-[PA/BT] spring return to 0, reduced leak oil 1,75
HK DHE 0713 P X 00AC 4/3 positive (closed) 3 [PB/AT]-[ABT/P]-[PA/BT] spring return to 0, reduced leak oil 1,75
Piston type example: [A/B/PT] = [A blocked / B blocked / P+T connected]

Order hints

Further circuits and versions, volumetric flows and switching power limits on request

Disclaimer

Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.