HK DHE X 00 DC

Solenoid-operated directional control valve size 6 without coil

  • Image_1 Image_1
  • Image_2 Image_2

Properties

Connection ISO/Cetop 03 size 6
Design 4/2-way valve or 4/3-way valve
3-chamber valve
with manual emergency operation
for DC coils
Max. operating pressure P, A, B: max. 350 bar / T: max. 210 bar
Mounting 4 pcs. socket head screw M5x30 12.9
Scope of supply without coil or plug
Volumetric flow max. 80 l/min (note characteristic curves)

Description

Can only be used for DC coils
switching capacity limits see characteristic curves

Hints

Valves marked with (P) are leak oil reduced valves. With flow quantities of >70 % of the nominal values here, an increased drop in pressure is to be expected.
Leak oil reduced valves are also used as pilot valves for pilot-controlled solenoid-operated directional control valves.
When using a leak oil-reduced valve type HK DH* 0711 P *** as a pilot valve, the centre position of the main valve is overridden.
The O-rings (NBR 70° Shore A) for the valve port can be ordered as spare part separately under the following article number: 4 pieces OR8.73-1.78

Article Table

Product Name Overlap Type Piston type Weight kg Version
Product Name Overlap Type Piston type Weight kg Version
HK DHE 0610 X 00DC negative (open) 4/2 0 [PB/AT]-[ABPT] 1.35 Spring return
HK DHE 0611 X 00DC positive (closed) 4/2 1 [PB/AT]-[A/B/P/T] 1.35 Spring return
HK DHE 0613 X 00DC positive (closed) 4/2 3 [PB/AT]-[ABT/P] 1.35 Spring return
HK DHE 0614 X 00DC negative (open) 4/2 4 [PA/BT]-[A/B/PT] 1.35 Spring return
HK DHE 0630 2 X 00DC negative (open) 4/2 0/2 [PB/AT]-[PA/BT] 1.35 Spring return
HK DHE 0631 2A X 00DC positive (closed) 4/2 1/2 [PB/AT]-[PA/BT] 1.35 Spring return
HK DHE 0631 2 X 00DC positive (closed) 4/2 1/2 [PB/AT]-[PA/BT] 1.35 Spring return
HK DHE 0632 2 X 00DC positive (closed) 4/2 2/2 [PB/A/T]-[PA/B/T] 1.35 Spring return
HK DHE 0710 X 00DC negative (open) 4/3 0 [PB/AT]-[ABPT]-[PA/BT] 1.75 spring return to 0
HK DHE 0710 9 X 00DC negative (open) 4/3 09 [PB/AT]-[ABPT]-[PAB/T] 1.75 spring return to 0
HK DHE 0711 X 00DC positive (closed) 4/3 1 [PB/AT]-[A/B/P/T]-[PA/BT] 1.75 spring return to 0
HK DHE 0713 X 00DC positive (closed) 4/3 3 [PB/AT]-[ABT/P]-[PA/BT] 1.75 spring return to 0
HK DHE 0714 X 00DC negative (open) 4/3 4 [PA/BT]-[A/B/PT]-[PB/AT] 1.75 spring return to 0
HK DHE 0714 8 X 00DC negative (open) 4/3 4/8 [PA/BT]-[A/B/PT]-[PB/AT] 1.75 spring return to 0, fine control notches
HK DHE 0714 9 X 00DC positive (closed) 4/3 49 [PA/BT]-[A/B/PT]-[PAB/T] 1.75 spring return to 0
HK DHE 0716 X 00DC positive (closed) 4/3 6 [PB/AT]-[AT/P/B]-[PA/BT] 1.75 spring return to 0
HK DHE 0717 X 00DC positive (closed) 4/3 7 [PB/AT]-[A/P/BT]-[PA/BT] 1.75 spring return to 0
HK DHE 0718 X 00DC positive (closed) 4/3 8 [PB/AT]-[PAB/T]-[PA/BT] 1.75 spring return to 0
HK DHE 0719 1 X 00DC positive (closed) 4/3 91 [PAB/T]-[A/B/P/T]-[PA/BT] 1.75 spring return to 0
HK DHE 0751 2 X 00DC positive (closed) 4/2 1/2 [PB/AT]-[PA/BT] 1.35 2 latching positions
HK DHE 0711 P X 00DC positive (closed) 4/3 1 [PB/AT]-[A/B/P/T]-[PA/BT] 1.75 spring return to 0, reduced leak oil
HK DHE 0713 P X 00DC positive (closed) 4/3 3 [PB/AT]-[ABT/P]-[PA/BT] 1.75 spring return to 0, reduced leak oil
Piston type example: [A/B/PT] = [A blocked / B blocked / P+T connected]

Order hints

Further circuits and versions, volumetric flows and switching power limits on request

Disclaimer

Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.