HK DHZE A

Proportional solenoid-operated directional control valve size 6



Properties

Connection ISO/Cetop 03 size 6
Design 4/2-way valve or 4/3-way valve, direct-controlled, for applications in open control loop
Scope of supply with coil, without plug
Operating pressure P, A, B: max. 350bar / T: max. 210bar

Description

Completely encapsulated solenoid coils
Response time < 30 ms
Hysteresis < 5%
Without integrated position transducer (a pcb Type HK EBM AS is required for control)

Article Table

Product Name Type Q max. L/min Overlap Control Design Piston type Weight kg
Product Name Type Q max. L/min Overlap Control Design Piston type Weight kg
HK DHZE A 051 L5 4/2 70 P, A, B, T positive (closed) linear Spring return L5 [A/B/P/T]-[PA/BT] 1,5
HK DHZE A 071 D5 4/3 70 P, A, B, T positive (closed) progressive, passage A, B in ratio 2:1 Spring return D5 [PB/AT]-[A/B/P/T]-[PA/BT] 2,0
HK DHZE A 071 S3 4/3 45 P, A, B, T positive (closed) progressive spring return to 0 S3 [PB/AT]-[A/B/P/T]-[PA/BT] 2,0
HK DHZE A 071 L5 4/3 70 P, A, B, T positive (closed) linear spring return to 0 L5 [PB/AT]-[A/B/P/T]-[PA/BT] 2,0
HK DHZE A 073 D5 4/3 70 P positive (closed); A, B, T negative (open) progressive, passage A, B in ratio 2:1 spring return to 0 D5 [PB/AT]-[ABT/P]-[PA/BT] 2,0
HK DHZE A 073 S3 4/3 45 P positive (closed); A, B, T negative (open) progressive spring return to 0 S3 [PB/AT]-[ABT/P]-[PA/BT] 2,0
HK DHZE A 073 L5 4/3 70 P positive (closed); A, B, T negative (open) linear spring return to 0 L5 [PB/AT]-[ABT/P]-[PA/BT] 2,0
Qmax - max intake volumetric flow - Piston type example: [A/B/PT] = [A blocked / B blocked / P+T connected]

Order hints

Other designs available on request

Disclaimer

Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.