HK DKE X 00 DC

Solenoid-operated directional control valve size10 without coil



Properties

Connection ISO/Cetop 05 size 10
Design 4/2-way valve or 4/3-way valve, 5-chamber valve, for DC coils, with manual emergency operation
Mounting 4 pcs. socket head screw M6x40 12.9
Scope of supply without coil or plug
Operating pressure P, A, B: max. 315bar / T: max. 210bar
Volumetric flow max. 120 l/min (note characteristic curves)

Description

Can only be used for DC coils
switching capacity limits see characteristic curves

Article Table

Product Name Type Overlap Piston type Design Weight kg
Product Name Type Overlap Piston type Design Weight kg
HK DKE 1 610 X00DC 4/2 negative (open) 0 [PB/AT]-[ABPT] Spring return 3,8
HK DKE 1 611 X00DC 4/2 positive (closed) 1 [PB/AT]-[A/B/P/T] Spring return 3,8
HK DKE 1 613 X00DC 4/2 positive (closed) 3 [PB/AT]-[ABT/P] Spring return 3,8
HK DKE 1 631 2 X00DC 4/2 positive (closed) 1/2 [PB/AT]-[PA/BT] Spring return 3,8
HK DKE 1 631 2 A X00DC 4/2 positive (closed) 1/2 [PB/AT]-[PA/BT] Spring return 3,8
HK DKE 1 632 2 X00DC 4/2 positive (closed) 2/2 [PB/A/T]-[PA/B/T] Spring return 3,8
HK DKE 1 710 X00DC 4/3 negative (open) 0 [PB/AT]-[ABPT]-[PA/BT] spring return to 0 4,1
HK DKE 1 711 X00DC 4/3 positive (closed) 1 [PB/AT]-[A/B/P/T]-[PA/BT] spring return to 0 4,1
HK DKE 1 713 X00DC 4/3 positive (closed) 3 [PB/AT]-[ABT/P]-[PA/BT] spring return to 0 4,1
HK DKE 1 714 X00DC 4/3 negative (open) 4 [PA/BT]-[A/B/PT]-[PB/AT] spring return to 0 4,1
HK DKE 1 751 2 X00DC 4/2 positive (closed) 1/2 [PB/AT]-[PA/BT] 2 latching positions 3,8
Piston type example: [A/B/PT] = [A blocked / B blocked / P+T connected]

Order hints

Further circuits and versions, volumetric flows and switching power limits on request

Disclaimer

Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.