HK DPH 4

Directional control valve NG25

Properties

Connection ISO/Cetop 08 NG25
Design 4/3-way valve (without pilot valve), pilot-controlled
Max. operating pressure P, A, B: max. 350 bar / T: max. 210 bar
Mounting 6 No. hex. socket head screw M12x50 12.9
Volumetric flow max. 650 l/min (note characteristic curves)

Description

These valves are actuated by a leak oil-reduced
solenoid-operated directional control valve size 6 set up as a pilot valve (type HK DHE *P*).
Control is internal
but conversion to external is possible.
The minimum control pressure for correct functioning is 8 bar. With the version with the control pressure generator
an additional pressure drop occurs
which ensures the minimum required control pressure for correct functioning. The version with the control pressure generator must be used if the pressure drop in the valve is below the minimum control pressure.

Hints

Die O-Ringe (NBR 70° Shore A) für die Ventilanschlussfläche können als Ersatzteil separat unter folgender Artikelnummer bestellt werden: 4 Stück OR22.
22-2.
62 und 3 Stück OR9.
13-2.
62

Article Table

Product Name Überdeckung Gewicht kg Art Kolbentyp Ausführung
Product Name Überdeckung Gewicht kg Art Kolbentyp Ausführung
HKDPH4710DRSPIL negative (open) 12.2 kg 4/3 0 [PB/AT]-[ABPT]-[PA/BT] Spring return, control pressure generator
HKDPH4711DSPIL positive (closed) 12.2 kg 4/3 1 [PB/AT]-[A/B/P/T]-[PA/BT] Spring return
HKDPH4713DSPIL positive (closed) 12.2 kg 4/3 3 [PB/AT]-[ABT/P]-[PA/BT] Spring return
HKDPH4714DRSPIL negative (open) 12.2 kg 4/3 4 [PA/BT]-[A/B/PT]-[PB/AT] Spring return, control pressure generator
Piston type example: [A/B/PT] = [A blocked / B blocked / P+T connected]

Order hints

Weitere Schaltungen und Ausführungen sowie Volumenströme und Schaltleistungsgrenzen auf Anfrage

Disclaimer

Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.