HK EMDV

2/2-way solenoid-controlled seat valve EMDV

  • Image_1 Image_1
  • Image_2 Image_2
  • Image_3 Image_3

Properties

Max. operating pressure max. 350 bar
Scope of supply with coil, without plug

Hints

Caution! Type HKEMDV10N01/NC1 valves are not seat valves Please use rectifier plug HKSP669 for HKEMDV08***230AC valves
Tightening torque for valve size 08 with Alu housing: 34-41 Nm
Tightening torque for valve size 08 with Steel housing: 47-54 Nm
Tightening torque for valve size 10 with Alu housing: 47-54 Nm
Tightening torque for valve size 10 with Steel housing: 74-81 Nm
Tightening torque for valve size 12 with Alu housing: 74-81 Nm
Tightening torque for valve size 12 with Steel housing: 95-102 Nm

Article Table

Product Name Screw-in housing A mm Rated voltage/brcurrent type Control B mm Volumetric flow max. l/min Weight kg C mm Screw-in thread Version
Product Name Screw-in housing A mm Rated voltage/brcurrent type Control B mm Volumetric flow max. l/min Weight kg C mm Screw-in thread Version
HK EMDV 08 N08 12DC HK GEH 38 C 0820 78.7 12 VDC pilot-controlled 27.9 38.0 0.36 34.3 SAE 8/2 3/4"-16UNF-2B (1)
HK EMDV 08 N08 24DC HK GEH 38 C 0820 78.7 24 VDC pilot-controlled 27.9 38.0 0.36 34.3 SAE 8/2 3/4"-16UNF-2B (1)
HK EMDV 08 N08 230AC HK GEH 38 C 0820 78.7 230 VAC pilot-controlled 27.9 38.0 0.36 34.3 SAE 8/2 3/4"-16UNF-2B (1)
HK EMDV 08 NC8 12DC HK GEH 38 C 0820 71.1 12 VDC pilot-controlled 27.9 38.0 0.36 34.3 SAE 8/2 3/4"-16UNF-2B (1)
HK EMDV 08 NC8 24DC HK GEH 38 C 0820 71.1 24 VDC pilot-controlled 27.9 38.0 0.36 34.3 SAE 8/2 3/4"-16UNF-2B (1)
HK EMDV 08 NC8 230AC HK GEH 38 C 0820 71.1 230 VAC pilot-controlled 27.9 38.0 0.36 34.3 SAE 8/2 3/4"-16UNF-2B (1)
HK EMDV 08 NC3 12DC HK GEH 38 C 0820 78.7 12 VDC directly controlled 27.9 19.0 0.41 34.3 SAE 8/2 3/4"-16UNF-2B (1)
HK EMDV 08 NC3 24DC HK GEH 38 C 0820 78.7 24 VDC directly controlled 27.9 19.0 0.41 34.3 SAE 8/2 3/4"-16UNF-2B (1)
HK EMDV 08 NC3 230AC HK GEH 38 C 0820 78.7 230 VAC directly controlled 27.9 19.0 0.41 34.3 SAE 8/2 3/4"-16UNF-2B (1)
HK EMDV 10 N01 12DC HK GEH 38 C1020 93.2 12 VDC directly controlled 32.5 30.0 0.88 45.2 SAE 10/2 7/8"-14UNF-2B (2)
HK EMDV 10 N01 24DC HK GEH 38 C1020 93.2 24 VDC directly controlled 32.5 30.0 0.88 45.2 SAE 10/2 7/8"-14UNF-2B (2)
HK EMDV 10 N01 230AC HK GEH 38 C1020 93.2 230 VAC directly controlled 32.5 30.0 0.88 45.2 SAE 10/2 7/8"-14UNF-2B (2)
HK EMDV 10 NC1 12DC HK GEH 38 C1020 93.2 12 VDC directly controlled 32.5 30.0 0.88 45.2 SAE 10/2 7/8"-14UNF-2B (2)
HK EMDV 10 NC1 24DC HK GEH 38 C1020 93.2 24 VDC directly controlled 32.5 30.0 0.88 45.2 SAE 10/2 7/8"-14UNF-2B (2)
HK EMDV 10 NC1 230AC HK GEH 38 C1020 93.2 230 VAC directly controlled 32.5 30.0 0.88 45.2 SAE 10/2 7/8"-14UNF-2B (2)
HK EMDV 12 N04 12DC HK GEH 12 C1220
HK GEH 34 C1220
90.5 12 VDC pilot-controlled 44.4 136.0 0.90 45.2 SAE 12/2 1.1/16"-12UNF-2B (2)
HK EMDV 12 N04 24DC HK GEH 12 C1220
HK GEH 34 C1220
90.5 24 VDC pilot-controlled 44.4 136.0 0.90 45.2 SAE 12/2 1.1/16"-12UNF-2B (2)
HK EMDV 12 N04 230AC HK GEH 12 C1220
HK GEH 34 C1220
90.5 230 VAC pilot-controlled 44.4 136.0 0.90 45.2 SAE 12/2 1.1/16"-12UNF-2B (2)
HK EMDV 12 NC4 12DC HK GEH 12 C1220
HK GEH 34 C1220
90.5 12 VDC pilot-controlled 44.4 136.0 0.90 45.2 SAE 12/2 1.1/16"-12UNF-2B (1)
HK EMDV 12 NC4 24DC HK GEH 12 C1220
HK GEH 34 C1220
90.5 24 VDC pilot-controlled 44.4 136.0 0.90 45.2 SAE 12/2 1.1/16"-12UNF-2B (1)
HK EMDV 12 NC4 230AC HK GEH 12 C1220
HK GEH 34 C1220
90.5 230 VAC pilot-controlled 44.4 136.0 0.90 45.2 SAE 12/2 1.1/16"-12UNF-2B (1)
(1) without manual emergency operation
(2) with manual emergency operation

Disclaimer

Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.