HK PCFC

2-way directional flow control valve PCFC

Properties

Design pressure-compensated
Max. operating pressure max. 300 bar

Description

Setting via setscrew
max. deviation: 5%
Only adjust valves in depressurized state!

Hints

These valves must be set according to the application.
Tightening torque for valve size 08 with Alu housing: 34-41 Nm
Tightening torque for valve size 08 with Steel housing: 47-54 Nm
Tightening torque for valve size 10 with Alu housing: 47-54 Nm
Tightening torque for valve size 10 with Steel housing: 74-81 Nm
Tightening torque for valve size 12 with Alu housing: 74-81 Nm
Tightening torque for valve size 12 with Steel housing: 95-102 Nm

Article Table

Product Name Setting range with Qon min. l/min Screw-in housing Q min. l/min A mm B mm Setting range with Qon max. l/min Weight kg Q max. l/min Screw-in thread
Product Name Setting range with Qon min. l/min Screw-in housing Q min. l/min A mm B mm Setting range with Qon max. l/min Weight kg Q max. l/min Screw-in thread
HK PCFC 08 NS0 02 4.0 HK GEH 38 C 0820 8 41.0 28.0 8.0 0.17 22 SAE 8/2 3/4"-16UNF-2B
HK PCFC 08 NS0 03 5.5 HK GEH 38 C 0820 11 41.0 28.0 11.0 0.17 22 SAE 8/2 3/4"-16UNF-2B
HK PCFC 08 NS0 05 9.5 HK GEH 38 C 0820 19 41.0 28.0 19.0 0.17 22 SAE 8/2 3/4"-16UNF-2B
HK PCFC 10 NS0 08 15.0 HK GEH 38 C1020 30 48.3 32.5 30.0 0.17 45 SAE 10/2 7/8"-14UNF-2B
HK PCFC 12 NS0 15 28.5 HK GEH 12 C1220
HK GEH 34 C1220
57 49.8 44.5 57.0 0.17 90 SAE 12/2 1.1/16"-12UNF-2B
HK PCFC 12 NS0 20 38.0 HK GEH 12 C1220
HK GEH 34 C1220
76 49.8 44.5 76.0 0.17 90 SAE 12/2 1.1/16"-12UNF-2B
Qein - intake volumetric flow
Qmax - max intake volumetric flow
Qmin - min. volumetric flow for control function

Disclaimer

Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.