HK QV

Flow control valve for plate mounting Cetop

Properties

Connection ISO/Cetop 03 NG6 (nur A + B)
Design HK QV 06 - directly controlled
Max. operating pressure max. 250 bar
Mounting 4 No. hex. socket head screw M5x70 12.9

Description

Flow rate is kept constant by a pressure balance
An integrated bypass non-return valve in the 2-way version permits flow in the opposite direction
Setting of the flow rate by means of adjustment knob

Article Table

Product Name Pressure difference Δp bar Weight kg Control range min. l/min Control range max. l/min Connections max. return flow B-A max. l/min Version
Product Name Pressure difference Δp bar Weight kg Control range min. l/min Control range max. l/min Connections max. return flow B-A max. l/min Version
HK QV 06 1 3 1.2 0.1 1.5 ISO/Cetop 03-2 NG6 24 2-way
HK QV 06 6 3 1.2 0.1 6.0 ISO/Cetop 03-2 NG6 24 2-way
HK QV 06 11 5 1.2 0.1 11.0 ISO/Cetop 03-2 NG6 24 2-way
HK QV 06 16 7 1.2 0.1 16.0 ISO/Cetop 03-2 NG6 24 2-way
HK QV 06 24 8 1.2 0.1 24.0 ISO/Cetop 03-2 NG6 24 2-way
Δp = min. pressure differential for control function

Disclaimer

Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.