HK SP 42C

Coil for solenoid-operated directional control valve HK42C

  • Image_1 Image_1

Properties

Corresponding connectors HKSP664, HKSP666, HKSP667, HKSP668

Hints

As far as AC coils are concerned, power input is considerably higher in the take-up phase than in the stopping phase. These must therefore never be operated without a magnet core since there is a danger of overheating and the coil can burn through. A similar effect occurs if valves with AC magnets are operated with extremely high pulse frequencies (On / Off). In such cases the coils, which are often in the vicinity of the high power input, can also overheat. For such applications the use of RC coils with rectifier plugs is recommended.
With DC coils extremely high power spikes can occur during powering down. We therefore recommend the use of plugs with protective circuits when using such coils.

Article Table

Product Name Average current consumption A Average power consumption W Weight kg Nominal voltage +/- 10 %
Product Name Average current consumption A Average power consumption W Weight kg Nominal voltage +/- 10 %
HK SP 12V 42C 3.13 37 1.10 12 VDC
HK SP 24V 42C 1.50 36 1.10 24 VDC
HK SP 205V 42C 0.18 36 1.10 205 VDC
HK SP 115V 42C 0.99 41 0.52 115 VAC
HK SP 230V 42C 0.50 41 0.52 230 VAC

Order hints

Other types of coil on request

Disclaimer

Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.