HK SP CO

Coil for HKDH solenoid-operated valve


Properties

Scope of supply with O-ring
Corresponding connectors HKSP664, HKSP666, HKSP667, HKSP668, HKSP669 (rectifier plug)

Hints

As far as AC coils are concerned, power input is considerably higher in the take-up phase than in the stopping phase. These must therefore never be operated without a magnet core since there is a danger of overheating and the coil can burn through. A similar effect occurs if valves with AC magnets are operated with extremely high pulse frequencies (On / Off). In such cases the coils, which are often in the vicinity of the high power input, can also overheat. For such applications the use of RC coils with rectifier plugs is recommended.
With DC coils extremely high power spikes can occur during powering down. We therefore recommend the use of plugs with protective circuits when using such coils.
Tightening torque for attaching nuts of the solenoid coils: 3Nm
Please use rectifier plug HKSP669 for solenoid coils type RC.

Article Table

Product Name Nominal voltage +/- 10 % for valve type Average power consumption W Average current consumption A Weight kg
Product Name Nominal voltage +/- 10 % for valve type Average power consumption W Average current consumption A Weight kg
HK SP COU 12DC 12 VDC HK DHI 33 2,80 0,25
HK SP COU 24DC 24 VDC HK DHI 33 1,40 0,25
HK SP COU 28DC 28 VDC HK DHI 35 1,24 0,25
HK SP COI 110AC 110 VAC HK DHI 60 0,50 0,18
HK SP COI 230AC 230 VAC HK DHI 60 0,25 0,25
HK SP COU 230 RC 230 VRC HK DHI 40 0,25 0,25
HK SP COE 12DC 12 VDC HK DHE DC 30 2,80 0,30
HK SP COE 24DC 24 VDC HK DHE DC 30 1,40 0,30
HK SP COE 28DC 28 VDC HK DHE DC 30 1,24 0,30
HK SP COER 230AC 230 VAC HK DHER AC 30 0,25 0,30
HK SP COE 110AC 110 VAC HK DHE AC 30 0,50 0,30
HK SP COE 230AC 230 VAC HK DHE AC 30 0,25 0,30
HK SP COE 230RC 230 VRC HK DHE DC 58 0,25 0,30

Order hints

Other types of coil on request

Disclaimer

Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.