XRD VA

Non-return valve, connector

  • Image_1 Image_1
  • Image_2 Image_2

Properties

Connection 1 + 2 metric cylindrical outer thread
Design Non-return valve, connector
Material Stainless steel
Scope of supply Socket (without union nut and cutting ring)
Sealing form 1 + 2 24° inner cone
Standard DIN 3865

Hints

Information about fitting, installation, pressure loads and permissible operating temperatures can be found in the technical information for pipe fittings.

Article Table

Product Name L1 mm L2 mm Operating pressure S1 S3 Opening pressure Series Ø d2 mm S2
Product Name L1 mm L2 mm Operating pressure S1 S3 Opening pressure Series Ø d2 mm S2
XRD NW 04 HL VA 58.0 29.0 PN 250 19 14 approx. 1 bar L 6 17
XRD NW 06 HL VA 59.0 30.0 PN 250 24 17 approx. 1 bar L 8 22
XRD NW 08 HL VA 69.5 40.5 PN 250 27 19 approx. 1 bar L 10 24
XRD NW 10 HL VA 72.5 43.5 PN 250 30 22 approx. 1 bar L 12 27
XRD NW 13 HL VA 77.5 47.5 PN 250 36 27 approx. 1 bar L 15 32
XRD NW 16 HL VA 83.5 51.5 PN 160 41 32 approx. 1 bar L 18 38
XRD NW 20 HL VA 93.5 61.5 PN 160 50 36 approx. 1 bar L 22 46
XRD NW 25 HL VA 102.5 69.5 PN 100 60 41 approx. 1 bar L 28 55
XRD NW 32 HL VA 117.5 74.5 PN 100 70 50 approx. 1 bar L 35 65
XRD NW 40 HL VA 119.0 74.0 PN 100 70 60 approx. 1 bar L 42 65
XRD NW 03 HS VA 63.5 34.5 PN 400 19 17 approx. 1 bar S 6 17
XRD NW 04 HS VA 63.5 34.5 PN 400 19 19 approx. 1 bar S 8 17
XRD NW 06 HS VA 72.5 40.5 PN 400 24 22 approx. 1 bar S 10 22
XRD NW 08 HS VA 74.5 42.5 PN 400 27 24 approx. 1 bar S 12 24
XRD NW 10 HS VA 82.5 47.5 PN 315 32 27 approx. 1 bar S 14 27
XRD NW 13 HS VA 86.5 50.5 PN 315 36 30 approx. 1 bar S 16 32
XRD NW 16 HS VA 97.5 54.5 PN 250 41 36 approx. 1 bar S 20 38
XRD NW 20 HS VA 106.5 58.5 PN 250 50 46 approx. 1 bar S 25 46
XRD NW 25 HS VA 122.5 69.5 PN 250 60 50 approx. 1 bar S 30 55
XRD NW 32 HS VA 136.5 75.5 PN 250 70 60 approx. 1 bar S 38 65
Ø = External pipe diameter
Series: LL = Very light L = Light S = Heavy
PN = Nominal pressure PB = Max. operating pressure

Order hints

Also available with opening pressure of 0.2; 0.5; 2; 3; 5 bar.

Disclaimer

Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.