AFG JIC (6000 PSI)

SAE external thread flange

  • Image_1 Image_1
  • Image_2 Image_2

Properties

Construction straight
Design SAE external thread flange
Material S355J2G3 (ST52.3)
Mounting Screw bore hole
Pressure series 6000 psi
Scope of supply flange only
Standard SAE J 518 C
ISO 6162
Surface black oiled

Hints

The stated maximum working pressure relates to the flange. The actual working pressure is determined by the pipe (wall thickness) and the quality of the pipe.
Recommended screws are listed in the columns M (metr) and M (unc).

Article Table

Product Name PB bar H mm Size Ø B mm D mm E mm A L mm M metr. C mm G mm M unc F mm L Footn
Product Name PB bar H mm Size Ø B mm D mm E mm A L mm M metr. C mm G mm M unc F mm L Footn
AFG 401 JIC 3/4 400 16 1/2" 9.9 SAE external thread flange; flange only; S355J2G3 (ST52.3) 56 18.2 UNF 3/4" -16 9.0 M 8 x 30 40.5 60 5/16" x 1.1/4" 48 -
AFG 401 JIC 7/8 400 16 1/2" 12.3 SAE external thread flange; flange only; S355J2G3 (ST52.3) 56 18.2 UNF 7/8" -14 9.0 M 8 x 30 40.5 60 5/16" x 1.1/4" 48 -
AFG 402 JIC 1 1/16 400 19 3/4" 15.5 SAE external thread flange; flange only; S355J2G3 (ST52.3) 71 23.8 UNF 1 1/16" -12 11.5 M 10 x 35 50.8 73 3/8" x 1.1/2" 60 -
AFG 403 JIC 1 5/16 400 24 1" 21.5 SAE external thread flange; flange only; S355J2G3 (ST52.3) 81 27.8 UN 1.5/16" -12 13.0 M 12 x 45 57.2 82 7/16" x 1.3/4" 70 -
AFG 404 JIC 1 5/16 400 27 1.1/4" 21.5 SAE external thread flange; flange only; S355J2G3 (ST52.3) 95 31.8 UN 1.5/16" -12 - M 14 x 50 66.7 92 1/2" x 1.3/4" 78 = 15.0 for metric screws; 13.5 for UNC screws
AFG 404 JIC 1 5/8 400 27 1.1/4" 27.5 SAE external thread flange; flange only; S355J2G3 (ST52.3) 95 31.8 UN 1.5/8" -12 - M 14 x 50 66.7 92 1/2" x 1.3/4" 78 = 15.0 for metric screws; 13.5 for UNC screws
AFG 405 JIC 1 7/8 400 30 1.1/2" 33.0 SAE external thread flange; flange only; S355J2G3 (ST52.3) 113 36.5 UN 1.7/8" -12 17.5 M 16 x 50 79.4 96 5/8" x 2" 95 -
Series: LL = Very light L = Light S = Heavy
Ø = External pipe diameter
PN = Nominal pressure
PB = Max. operating pressure

Disclaimer

Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.