AFS G (6000 PSI)

SAE screw-in flange, BSP

  • Image_1 Image_1
  • Image_2 Image_2

Properties

Construction straight
Design SAE screw-in flange
Material S355J2G3 (ST52.3)
Mounting Screw bore hole
Pressure series 6000 psi
Scope of supply flange only
Standard SAE J 518 C
ISO 6162
Surface black oiled

Hints

The stated maximum working pressure relates to the flange. The actual working pressure is determined by the pipe (wall thickness) and the quality of the pipe.
Recommended screws are listed in the columns M (metr) and M (unc).

Article Table

Product Name Size PB 10.9 bar H mm E mm C mm Ø B mm M metr. D mm A L mm M unc G mm F mm L Footn
Product Name Size PB 10.9 bar H mm E mm C mm Ø B mm M metr. D mm A L mm M unc G mm F mm L Footn
AFS 401 G 1/2 1/2" 400 16 18.2 40.5 13 M 8 x 30 54 G 1/2" -14 9 5/16" x 1.1/4" 36 46 -
AFS 401 G 3/8 1/2" 400 16 18.2 40.5 13 M 8 x 30 54 G 3/8" -19 9 5/16" x 1.1/4" 36 46 -
AFS 402 G 1/2 3/4" 400 21 23.8 50.8 13 M 10 x 35 71 G 1/2" -14 11 3/8" x 1.1/2" 35 55 -
AFS 402 G 3/4 3/4" 400 21 23.8 50.8 19 M 10 x 35 71 G 3/4" -14 11 3/8" x 1.1/2" 35 55 -
AFS 403 G 3/4 1" 400 25 27.8 57.2 19 M 12 x 45 81 G 3/4" -14 13 7/16" x 1.3/4" 42 65 -
AFS 403 G 1 1" 400 25 27.8 57.2 25 M 12 x 45 81 G 1" -11 13 7/16" x 1.3/4" 42 65 -
AFS 404 G 1 1.1/4" 400 27 31.8 66.7 25 M 14 x 45 95 G 1" -11 - 1/2" x 1.3/4" 45 78 = 15.0 for metric screws; 13.5 for UNC screws
AFS 404 G 1 1/4 1.1/4" 400 27 31.8 66.7 32 M 14 x 45 95 G 1.1/4" -11 - 1/2" x 1.3/4" 45 78 = 15.0 for metric screws; 13.5 for UNC screws
AFS 405 G 1 1/4 1.1/2" 400 30 36.5 79.4 32 M 16 x 50 112 G 1.1/4" -11 17 5/8" x 2" 50 94 -
AFS 405 G 1 1/2 1.1/2" 400 30 36.5 79.4 38 M 16 x 50 112 G 1.1/2" -11 17 5/8" x 2" 50 94 -
AFS 406 G 1 1/2 2" 400 37 44.5 96.8 38 M 20 x 65 134 G 1.1/2" -11 21 3/4" x 2.1/2" 65 114 -
AFS 406 G 2 2" 400 37 44.5 96.8 51 M 20 x 65 134 G 2" -11 21 3/4" x 2.1/2" 65 114 -
PN = Nominal pressure PB = Max. operating pressure

Disclaimer

Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.