AFS SRE (6000 PSI)

SAE stub end

  • Image_1 Image_1
  • Image_2 Image_2

Properties

Construction straight
Design SAE stub end
Material S355J2G3 (ST52.3)
Mounting Screw bore hole
Pressure series 6000 psi
Scope of supply flange only
Standard SAE J 518 C
ISO 6162
Surface black oiled

Hints

The stated maximum working pressure relates to the flange. The actual working pressure is determined by the pipe (wall thickness) and the quality of the pipe.
Recommended screws are listed in the columns M (metr) and M (unc).

Article Table

Product Name H mm Size PB 10.9 bar Pipe E mm L mm C mm G mm M metr. M unc A mm B2 mm B1 mm
Product Name H mm Size PB 10.9 bar Pipe E mm L mm C mm G mm M metr. M unc A mm B2 mm B1 mm
AFS 401 SRE 20 16.0 1/2" 400 20 x 3 18.2 9.0 40.5 34.0 M 8 x 30 5/16" x 1.1/4" 20 14 14.0
AFS 402 SRE 20 21.0 3/4" 400 20 x 3 23.8 11.0 50.8 35.0 M 10 x 35 3/8" x 1.1/2" 20 14 14.0
AFS 402 SRE 25 21.0 3/4" 400 25 x 4 23.8 11.0 50.8 35.0 M 10 x 35 3/8" x 1.1/2" 25 17 17.0
AFS 403 SRE 25 25.0 1" 400 25 x 4 27.8 13.0 57.2 42.0 M 12 x 45 7/16" x 1.1/2" 25 17 17.0
AFS 403 SRE 30 25.0 1" 400 30 x 4 27.8 13.0 57.2 42.0 M 12 x 45 7/16" x 1.1/2" 30 22 22.0
AFS 404 SRE 30 25.0 1.1/4" 400 30 x 4 31.8 15.0 66.7 44.0 M 14 x 50 1/2" x 1.3/4" 30 22 22.0
AFS 404 SRE 38 25.0 1.1/4" 400 38 x 6 31.8 15.0 66.7 44.0 M 14 x 50 1/2" x 1.3/4" 38 26 26.0
AFS 405 SRE 38 28.0 1.1/2" 400 38 x 6 36.5 17.0 79.4 56.0 M 16 x 50 5/8" x 2" 38 26 26.0
AFS 405 SRE 48 28.0 1.1/2" 400 48.3 x 8 36.5 17.0 79.4 56.0 M 16 x 50 5/8" x 2" 49 32 32.0
AFS 405 SRE 60 27.0 1.1/2" 400 60.3 x 10 36.5 17.0 79.4 56.0 M 16 x 50 5/8" x 2" 61 38 40.0
AFS 406 SRE 60 37.0 2" 400 60.3 x 10 44.5 21.0 96.8 65.0 M 20 x 70 3/4" x 2.1/2" 61 40 40.0
AFS 406 SRE 76 33.0 2" 400 76.1 x 12.5 44.5 21.0 96.8 80.0 M 20 x 65 3/4" x 2.1/2" 76 48 50.0
PN = Nominal pressure PB = Max. operating pressure

Disclaimer

Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.