HK 2P 1 FSRA

Gear pump, size 2 FSRA

  • Image_1 Image_1
  • Image_2 Image_2

Properties

Design housing type BH (attachment top right-hand, bottom left-hand)
Material Housing: Aluminium
Front flange, end cover: Aluminium
Pitch circle pressure side 35 / M6
Pitch circle suction side 40 / M6

Description

German standard pump – hole pattern 60 x 60 – dia. 50 – taper 1:5 – flange fitting

Hints

Anzugsdrehmoment der Befestigungsmutter auf der Welle: 40 Nm

Article Table

Product Name VFU cm³ p1max. bar A mm Speed max. r/min p3max. bar Speed min. r/min Direction of rotation p2max. bar B mm Weight kg
Product Name VFU cm³ p1max. bar A mm Speed max. r/min p3max. bar Speed min. r/min Direction of rotation p2max. bar B mm Weight kg
HK 2P 41 11 FSRA 4.2 260 87.2 3500 300 700 anti-clockwise rotating 280 38.6 2.100
HK 2P 41 12 FSRA 4.2 260 87.2 3500 300 700 clockwise rotating 280 38.6 2.100
HK 2P 43 11 FSRA 6.0 260 90.2 3500 300 700 anti-clockwise rotating 280 38.6 2.200
HK 2P 43 12 FSRA 6.0 260 90.2 3500 300 700 clockwise rotating 280 38.6 2.200
HK 2P 45 11 FSRA 8.4 260 94.2 3500 300 700 anti-clockwise rotating 280 50.6 2.300
HK 2P 45 12 FSRA 8.4 260 94.2 3500 300 700 clockwise rotating 280 50.6 2.300
HK 2P 47 11 FSRA 10.8 260 98.2 3500 300 700 anti-clockwise rotating 280 45.0 2.400
HK 2P 47 12 FSRA 10.8 260 98.2 3500 300 700 clockwise rotating 280 45.0 2.400
HK 2P 49 11 FSRA 14.4 250 104.2 3500 290 700 anti-clockwise rotating 270 45.0 2.600
HK 2P 49 12 FSRA 14.4 250 104.2 3500 290 700 clockwise rotating 270 45.0 2.600
HK 2P 51 11 FSRA 16.8 230 108.2 3500 270 700 anti-clockwise rotating 250 45.0 2.700
HK 2P 51 12 FSRA 16.8 230 108.2 3500 270 700 clockwise rotating 250 45.0 2.700
HK 2P 53 11 FSRA 19.2 210 112.2 3000 250 700 anti-clockwise rotating 230 45.0 2.800
HK 2P 53 12 FSRA 19.2 210 112.2 3000 250 700 clockwise rotating 230 45.0 2.800
HK 2P 55 11 FSRA 22.8 200 118.2 3000 240 700 anti-clockwise rotating 220 52.5 2.950
HK 2P 55 12 FSRA 22.8 200 118.2 3000 240 700 clockwise rotating 220 52.5 2.950
VFU = conveying volume per revolution
p1 = continuous pressure
p2 = working pressure
p3 = maximum pressure

Order hints

Further pump versions available on request

Disclaimer

Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.