HK 42 C1 (7/G/Q/R)

Solenoid-operated directional control valve NG10

  • Image_1 Image_1
  • Image_2 Image_2

Properties

Connection ISO/Cetop 05 size 10
Design 4/2-way valve or 4/3-way valve
with manual emergency operation
Max. operating pressure P, A, B: max. 350 bar / T: max. 210 bar (VDC) / T: max. 105 bar (VAC)
Mounting 4 pcs. socket head screw M6x40 12.9
Scope of supply with coil, without plug
Volumetric flow max. 140 l/min (note characteristic curves)

Description

switching capacity limits see characteristic curves

Hints

The O-rings (NBR 70° Shore A) for the valve port can be ordered as spare part separately under the following article number: 5 pieces OR12.42-1.78

Article Table

Product Name Overlap Weight kg Type Rated voltage/brcurrent type Piston type Version
Product Name Overlap Weight kg Type Rated voltage/brcurrent type Piston type Version
HK 42 3151 0101 C1 R positive (closed) 3.4 4/2 12 VDC 51 [PB/AT]-[PA/BT] Spring return
HK 42 3151 0101 C1 Q positive (closed) 3.4 4/2 24 VDC 51 [PB/AT]-[PA/BT] Spring return
HK 42 3151 0101 C1 G positive (closed) 3.4 4/2 205 VDC 51 [PB/AT]-[PA/BT] Spring return
HK 42 3151 0101 C1 7 positive (closed) 3.4 4/2 230 VAC 50 Hz 51 [PB/AT]-[PA/BT] Spring return
HK 42 3111 0101 C1 R negative (open) 3.4 4/2 12 VDC 11 [PB/AT]-[PA/BT] Spring return
HK 42 3111 0101 C1 Q negative (open) 3.4 4/2 24 VDC 11 [PB/AT]-[PA/BT] Spring return
HK 42 3111 0101 C1 G negative (open) 3.4 4/2 205 VDC 11 [PB/AT]-[PA/BT] Spring return
HK 42 3111 0101 C1 7 negative (open) 3.4 4/2 230 VAC 50 Hz 11 [PB/AT]-[PA/BT] Spring return
HK 42 3151 0201 C1 R positive (closed) 3.4 4/2 12 VDC 51 [PB/AT]-[PA/BT] Spring return
HK 42 3151 0201 C1 Q positive (closed) 3.4 4/2 24 VDC 51 [PB/AT]-[PA/BT] Spring return
HK 42 3151 0201 C1 G positive (closed) 3.4 4/2 205 VDC 51 [PB/AT]-[PA/BT] Spring return
HK 42 3151 0201 C1 7 positive (closed) 3.4 4/2 230 VAC 50 Hz 51 [PB/AT]-[PA/BT] Spring return
HK 42 3101 0601 C1 R negative (open) 3.4 4/2 12 VDC 01 [PB/AT]-[ABPT] Spring return
HK 42 3101 0601 C1 Q negative (open) 3.4 4/2 24 VDC 01 [PB/AT]-[ABPT] Spring return
HK 42 3101 0601 C1 G negative (open) 3.4 4/2 205 VDC 01 [PB/AT]-[ABPT] Spring return
HK 42 3101 0601 C1 7 negative (open) 3.4 4/2 230 VAC 50 Hz 01 [PB/AT]-[ABPT] Spring return
HK 42 3103 0601 C1 R positive (closed) 3.4 4/2 12 VDC 03 [PB/AT]-[A/B/P/T] Spring return
HK 42 3103 0601 C1 Q positive (closed) 3.4 4/2 24 VDC 03 [PB/AT]-[A/B/P/T] Spring return
HK 42 3103 0601 C1 G positive (closed) 3.4 4/2 205 VDC 03 [PB/AT]-[A/B/P/T] Spring return
HK 42 3103 0601 C1 7 positive (closed) 3.4 4/2 230 VAC 50 Hz 03 [PB/AT]-[A/B/P/T] Spring return
HK 42 3108 0601 C1 R positive (closed) 3.4 4/2 12 VDC 08 [PB/AT]-[ABT/P] Spring return
HK 42 3108 0601 C1 Q positive (closed) 3.4 4/2 24 VDC 08 [PB/AT]-[ABT/P] Spring return
HK 42 3108 0601 C1 G positive (closed) 3.4 4/2 205 VDC 08 [PB/AT]-[ABT/P] Spring return
HK 42 3108 0601 C1 7 positive (closed) 3.4 4/2 230 VAC 50 Hz 08 [PB/AT]-[ABT/P] Spring return
HK 42 3107 0601 C1 R negative (open) 3.4 4/2 12 VDC 07 [PA/BT]-[A/B/PT] Spring return
HK 42 3107 0601 C1 Q negative (open) 3.4 4/2 24 VDC 07 [PA/BT]-[A/B/PT] Spring return
HK 42 3107 0601 C1 G negative (open) 3.4 4/2 205 VDC 07 [PA/BT]-[A/B/PT] Spring return
HK 42 3107 0601 C1 7 negative (open) 3.4 4/2 230 VAC 50 Hz 07 [PA/BT]-[A/B/PT] Spring return
HK 42 3172 0101 C1 R positive (closed) 3.4 4/2 12 VDC 72 [PA/B/T]-[PB/A/T] Spring return
HK 42 3172 0101 C1 Q positive (closed) 3.4 4/2 24 VDC 72 [PA/B/T]-[PB/A/T] Spring return
HK 42 3172 0101 C1 G positive (closed) 3.4 4/2 205 VDC 72 [PA/B/T]-[PB/A/T] Spring return
HK 42 3172 0101 C1 7 positive (closed) 3.4 4/2 230 VAC 50 Hz 72 [PA/B/T]-[PB/A/T] Spring return
HK 42 3201 0302 C1 R negative (open) 3.6 4/3 12 VDC 01 [PB/AT]-[ABPT]-[PA/BT] spring return to 0
HK 42 3201 0302 C1 Q negative (open) 3.6 4/3 24 VDC 01 [PB/AT]-[ABPT]-[PA/BT] spring return to 0
HK 42 3201 0302 C1 G negative (open) 3.6 4/3 205 VDC 01 [PB/AT]-[ABPT]-[PA/BT] spring return to 0
HK 42 3201 0302 C1 7 negative (open) 3.6 4/3 230 VAC 50 Hz 01 [PB/AT]-[ABPT]-[PA/BT] spring return to 0
HK 42 3203 0302 C1 R positive (closed) 3.6 4/3 12 VDC 03 [PB/AT]-[A/B/P/T]-[PA/BT] spring return to 0
HK 42 3203 0302 C1 Q positive (closed) 3.6 4/3 24 VDC 03 [PB/AT]-[A/B/P/T]-[PA/BT] spring return to 0
HK 42 3203 0302 C1 G positive (closed) 3.6 4/3 205 VDC 03 [PB/AT]-[A/B/P/T]-[PA/BT] spring return to 0
HK 42 3203 0302 C1 7 positive (closed) 3.6 4/3 230 VAC 50 Hz 03 [PB/AT]-[A/B/P/T]-[PA/BT] spring return to 0
HK 42 3208 0302 C1 R positive (closed) 3.6 4/3 12 VDC 08 [PB/AT]-[ABT/P]-[PA/BT] spring return to 0
HK 42 3208 0302 C1 Q positive (closed) 3.6 4/3 24 VDC 08 [PB/AT]-[ABT/P]-[PA/BT] spring return to 0
HK 42 3208 0302 C1 G positive (closed) 3.6 4/3 205 VDC 08 [PB/AT]-[ABT/P]-[PA/BT] spring return to 0
HK 42 3208 0302 C1 7 positive (closed) 3.6 4/3 230 VAC 50 Hz 08 [PB/AT]-[ABT/P]-[PA/BT] spring return to 0
HK 42 3207 0302 C1 R negative (open) 3.6 4/3 12 VDC 07 [PA/BT]-[A/B/PT]-[PB/AT] spring return to 0
HK 42 3207 0302 C1 Q negative (open) 3.6 4/3 24 VDC 07 [PA/BT]-[A/B/PT]-[PB/AT] spring return to 0
HK 42 3207 0302 C1 G negative (open) 3.6 4/3 205 VDC 07 [PA/BT]-[A/B/PT]-[PB/AT] spring return to 0
HK 42 3207 0302 C1 7 negative (open) 3.6 4/3 230 VAC 50 Hz 07 [PA/BT]-[A/B/PT]-[PB/AT] spring return to 0
HK 42 3751 0902 C1 R positive (closed) 3.6 4/2 12 VDC 51 [PB/AT]-[PA/BT] 2 latching positions
HK 42 3751 0902 C1 Q positive (closed) 3.6 4/2 24 VDC 51 [PB/AT]-[PA/BT] 2 latching positions
HK 42 3751 0902 C1 G positive (closed) 3.6 4/2 205 VDC 51 [PB/AT]-[PA/BT] 2 latching positions
HK 42 3751 0902 C1 7 positive (closed) 3.6 4/2 230 VAC 50 Hz 51 [PB/AT]-[PA/BT] 2 latching positions
Piston type example: [A/B/PT] = [A blocked / B blocked / P+T connected]

Order hints

Further circuits and versions, volumetric flows and switching power limits on request

Disclaimer

Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.