Cosa stai cercando?

Inserisci un criterio di ricerca

Siamo spiacenti!

Nessun risultato risultato trovato.

Christmas / New Year shipping times
Our central warehouses will be closed from 23.12.2024 to 01.01.2025. Incoming orders will not be shipped during this period. If necessary, you are welcome to use our branch network during this time. Customer service will be available as usual.

Please note that our branches may have different opening hours during the holidays. For up-to-date information, we recommend calling ahead or checking the current opening times on Google Maps. Due to technical reasons, we are currently unable to update the opening hours on our website. Link to branch search on Google Maps

Login

Sei un nuovo cliente?

Registrati e assicurati tanti vantaggi:

Verifica della disponibilità dei prodotti
Ordinazioni successive rapide e cronologia degli ordini
Raccomandazioni personali sui prodotti
Pagamento con fattura

Help & Contact

Contatta HANSA-FLEX

Hai domande sullo shop online o sui nostri prodotti?
Puoi contattare il nostro servizio clienti:

Lunedì - venerdì: dalle 8:00 alle 17:00
Domenica e festivi esclusi

Oppure puoi utilizzare le nostre FAQ

Troverai le risposte alle domande più frequenti
.

Helping people help themselves
Vai alle FAQ

K-DIGI DRUCKSCHA H 3 DURCHF PF2A

Digital Flow Switch high flow version PF2A
Tensione nominale
24 V DC 
Cavo I/O
without connection cable 
Grado di protezione
IP 65 
Scarica PDF

Caratteristiche

Tensione nominale
  • 24 V DC 
Cavo I/O
  • without connection cable 
Grado di protezione
  • IP 65 
Temperatura ambiente
  • 0 °C to +50 °C 
Temperatura del fluido
  • 0 °C to +50 °C 
Serie
  • PF2A 
Mezzi
  • aria e azoto 
Tipo
  • digital flow switch 
pressione d'esercizio max.
  • -50 kPa 
Customs tariff number
  • 90261021 
Tutte le caratteristiche

Descrizione del prodotto

Descrizione
Digital flow switch, series PF2A, for air and nitrogen, three output types: Switch, accumulated pulse and analogue outputs, switching from real-time flow rate to accumulated flow is possible, measuring range 1 to 10 l/min, media temperature 0 to 50 °C, operating temperature range 0 to 50 °C, repetition accuracy max. ±3% of the measuring range, temperature characteristic max. 5% of the measuring range. (0 to 50 °C, based on 25 °C), current consumption (no load) max. 170 mA, measuring principle thermistor (heating element), operating display 3-digit, 7-segment LED (illuminates at output signal ON OUT1: Green;OUT2: Red), operating pressure range –50 kPa... 0.5 MPa, switch output PNP open collector;internal voltage drop max. 1.5 V (at 80 mA working current);2 outputs, supply voltage 12 to 24 VDC, protection class IP 65, connection size G 1/4
Informazioni supplementari
For air and nitrogen
Three types of output: Switch, accumulated pulse and analog outputs
Switching of current flow to accumulated flow is possible

Varianti dei prodotti

5 Risultati
Denominazione
Corrente assorbita max. (mA)
Filetto dell'attacco
Campo di misurazione
Materiale
Dettagli / Pezzo
170 mA
G 1/4″ -19 
1 - 10 l/min 
max. ±3 % from scale 
Scopri di più
170 mA
G 3/8″ -19 
10 - 100 l/min 
max. ±3 % from scale 
Scopri di più
170 mA
G 3/8″ -19 
20 - 200 l/min 
max. ±3 % from scale 
Scopri di più
170 mA
G 1/4″ -19 
5 - 50 l/min 
max. ±1 % from scale 
Scopri di più
170 mA
G 1/2″ -14 
50 - 500 l/min 
max. ±3 % from scale 
Scopri di più

Column selection

Corrente assorbita max. (mA)
Filetto dell'attacco
Campo di misurazione
Materiale
pressione d'esercizio min. (MPa)