HK 100LA4 B5 2-4 IE3

E-Motor 230/400V 2,2kW 1455U B5 IE3
P 60 Hz
2,55 kW
n 60 Hz
1.765 r/min
P 50 Hz
2,2 kW
Download PDF
Product details for

HK 100LA4 B5 2-4 IE3

P 60 Hz
2,55 kW
n 60 Hz
1.765 r/min
P 50 Hz
2,2 kW
n 50 Hz
1.465 r/min
I 50 Hz
7,65 A
LF 50 Hz
0,83
Faktor IA/IN
7
η (IE3) %
87
C
280 mm
H1
171 mm
B
373 mm
Ø D Welle
28 mm
Ø E
180 mm
Ø F
250 mm
All characteristics

Characteristics

Schutzart
  • IP 55 
Umgebungstemperatur
  • -20 °C bis +40 °C 
Werkstoff
  • Gehäuse: Aluminium 
Ausführung
  • Bauform B5 
  • ohne Füße 
Zolltarifnummer
  • 85015220 
All characteristics

Product description

Notes
Achtung! Maß »B« kann je nach Ausführung geringfügig länger ausfallen.
Description
Eigengekühlte Käfigläufer-Energiesparmotoren
High Efficiency IE3 - IEC60034-30:2009
Bemessungsspannung 230/400 V 50 Hz, 460 V 60 Hz
4-polig
Spannungstoleranz ±5 %

Product variants

5 Results
Show dimensional drawing
Identifier
P 60 Hz (kW)
n 60 Hz (r/min)
P 50 Hz (kW)
n 50 Hz (r/min)
Details / items
0.86 kW
1,755 r/min
0.75 kW
1,450 r/min
Learn more
1.3 kW
1,740 r/min
1.1 kW
1,440 r/min
Learn more
1.75 kW
1,745 r/min
1.5 kW
1,445 r/min
Learn more
2.55 kW
1,765 r/min
2.2 kW
1,465 r/min
Learn more
3.45 kW
1,760 r/min
3 kW
1,460 r/min
Learn more
P 60 Hz = Nennleistung bei 400 V/60 Hz
n 50 Hz = Nenndrehzahl bei 400 V/50 Hz
n 60 Hz = Nenndrehzahl bei 400 V/60 Hz
I 50 Hz = Nennstrom bei 400 V/50 Hz
LF 50 Hz = Leistungsfaktor cos phi bei 50 Hz
P 50 Hz = Nennleistung bei 400 V/50 Hz
η (IE3) = Wirkungsgrad nach IE3 in % (bei Volllast)
Faktor IA/IN = Anlaufstrom IA / Nennstrom IN

Column selection

P 60 Hz (kW)
n 60 Hz (r/min)
P 50 Hz (kW)
n 50 Hz (r/min)
I 50 Hz (A)
LF 50 Hz
Factor IA / IN
η (IE3) %
C (mm)
H1 (mm)
B (mm)
Ø D shaft (mm)
Ø E (mm)
Ø F (mm)
P 60 Hz = Nennleistung bei 400 V/60 Hz
n 50 Hz = Nenndrehzahl bei 400 V/50 Hz
n 60 Hz = Nenndrehzahl bei 400 V/60 Hz
I 50 Hz = Nennstrom bei 400 V/50 Hz
LF 50 Hz = Leistungsfaktor cos phi bei 50 Hz
P 50 Hz = Nennleistung bei 400 V/50 Hz
η (IE3) = Wirkungsgrad nach IE3 in % (bei Volllast)
Faktor IA/IN = Anlaufstrom IA / Nennstrom IN