Helping people help themselves
SSS

HK 92RV 04 B 49

Gear flow divider 14 4 sec. 4 valves
p1 max.
200 bar
p2 max.
230 bar
Flow per element min.
16.8 l/min
PDF'in indirin
Ürün ayrıntıları:

HK 92RV 04 B 49

p1 max.
200 bar
p2 max.
230 bar
Flow per element min.
16.8 l/min
Flow per element rec'd
25.9 l/min
Flow per element max.
35 l/min
Input volume per section
14 cm³
A
64 mm
Li
512 mm
Tüm özellikler

Özellikler

Design
  • with one phase compensation valve and anti-cavitation valve per section 
  • external leak oil discharge 
  • adjustment range DBV: 70 - 210 bar 
Pressure difference
  • max. 30 bar (between the sections) 
Construction type
  • 4 sections 
Size
  • group 2 
Customs tariff number
  • 84122981 
Tüm özellikler

Ürün açıklaması

Uyarılar
Before commissioning the system, the first running-in of the gear flow divider should be under no load.
Diagrams and circuit diagrams essentially valid as schematic diagrams also for 4-way flow dividers.
Açıklama
This flow divider is used to supply four independent hydraulic circuits with just one pump.
Division error approx. 3 %.
Different pressure settings for each section possible.
Valves adjustable from 70 - 210 bar, other setting ranges on request.
Modification to internal leak oil discharge possible - for this, close off port T with G1/2″ blind plug (modification recommended only after consultation!).
After conversion to internal leak oil discharge, the function of the suction valves is disabled.
Configuration of gear flow dividers: qi = Q/z * 1000/n.
Qi = displacement/section [cm³].
Q = total input volume flow [l/min].
Z = number of sections.
N = rotating speed [rpm].
Ek bilgiler
Recommended speed: 1800 - 2000 rpm

Product variants

5 Results
Ölçü çizimini gösterin
Tanım
p1 max. (bar)
p2 max. (bar)
Flow per element min. (l/min)
Flow per element rec'd (l/min)
Ayrıntılar / items
210 bar
260 bar
4.8 l/min
7.6 l/min
Daha fazla bilgi edinin
210 bar
260 bar
7.2 l/min
10.8 l/min
Daha fazla bilgi edinin
210 bar
260 bar
10.8 l/min
15.1 l/min
Daha fazla bilgi edinin
210 bar
260 bar
13.2 l/min
19.4 l/min
Daha fazla bilgi edinin
200 bar
230 bar
16.8 l/min
25.9 l/min
Daha fazla bilgi edinin
p1 = max. working pressure
p2 = max. peak pressure

Column selection

p1 max. (bar)
p2 max. (bar)
Flow per element min. (l/min)
Flow per element rec'd (l/min)
Flow per element max. (l/min)
Input volume per section (cm³)
A (mm)
Li (mm)
p1 = max. working pressure
p2 = max. peak pressure