HK DPH 4 711 D SPIL

4/3-Wegeventil NG 25, ohne Pilotventil
Type
4/3 
Overlap
positive (closed) 
Piston type
1 [PB/AT]-[A/B/P/T]-[PA/BT] 
Preuzimanje PDF-a
Detalji o proizvodu za

HK DPH 4 711 D SPIL

Type
4/3
Overlap
positive (closed)
Piston type
1 [PB/AT]-[A/B/P/T]-[PA/BT]
Design
spring return

Svojstva

Max. working pressure
  • P, A, B: max. 350 bar / T: max. 210 bar 
Design
  • 4/3-way valve (without pilot valve) 
  • pilot operated 
Connection
  • ISO/Cetop 08 size 25 
Flow rate
  • max. 650 l/min (note characteristic curves) 
Mounting
  • 6 pcs. hexagon socket screw M 12 x 50 12.9 
  • Screw set HK M12 50 for 1 basic valve. In vertical stacking applications with sandwich plates, the use of the appropriate longer screws are required. 
Customs tariff number
  • 84812010 
Sva svojstva

Opis proizvoda

Napomene
The O-rings (NBR 90 Shore A) for the valve port can be ordered as spare part separately under the following article number: 4 pieces OR28.17-3.53N90 and 2 pieces OR13.94-2.62N90
Opis
These valves are actuated by a solenoid directional valve NG6 in leakage oil-reduced design (type HK DHE...P...) to be installed as a pilot valve.
Control is internal, but conversion to external is possible.
The minimum control pressure for correct function is 8 bar.
In the version with control pressure generator, an additional pressure drop is generated which ensures the minimum required control pressure for a correct switching function. The version with control pressure generator must be used if the pressure drop in the valve is below the minimum value of the control pressure.
Napomena o narudžbi
Further circuits and versions, volumetric flows and switching power limits are available on request

Product variants

4 Results
Prikaži crtež s dimenzijama
Oznaka
Type
Overlap
Piston type
Design
Detalji / items
4/3 
negative (open) 
0 [PB/AT]-[ABPT]-[PA/BT] 
spring return, control pressure generator 
Saznaj više
4/3 
positive (closed) 
1 [PB/AT]-[A/B/P/T]-[PA/BT] 
spring return 
Saznaj više
4/3 
positive (closed) 
3 [PB/AT]-[ABT/P]-[PA/BT] 
spring return 
Saznaj više
4/3 
negative (open) 
4 [PA/BT]-[A/B/PT]-[PB/AT] 
spring return, control pressure generator 
Saznaj više
Piston type example: [A/B/PT] = [A blocked / B blocked / P+T connected]

Column selection

Type
Overlap
Piston type
Design
Piston type example: [A/B/PT] = [A blocked / B blocked / P+T connected]