Kaj iščete?

Vnesite iskalni pojem

Žal nam je!

Ne najdem rezultatov iskanja.

Prijava

Ste nova stranka?

Registrirajte se in si zagotovite številne prednosti:

Preverjanje razpoložljivosti izdelka
Hitro naknadno naročanje in zgodovina naročil
Osebna priporočila za izdelke
Plačilo na račun

Help & Contact

Your direct line to us

If you have any questions about the online store or our products, you can call our customer service at:

Monday - Thursday: 8:00AM - 5:00PM
Friday: 8:00AM - 4:00PM
Except saturdays, sundays and holidays

Or use our FAQ

There you get answers to the most frequently asked questions.

Helping people help themselves
Pogosta vprašanja

HK 90S4 B35 2-4 IE3

E-Motor 230/400V 1,1kW 1400U B3/B5 IE3
Podrobnosti o izdelku za

HK 90S4 B35 2-4 IE3

P 60 Hz
1.3 kW
n 60 Hz
1,740 r/min
P 50 Hz
1.1 kW
n 50 Hz
1,440 r/min
I 50 Hz
4.17 A
LF 50 Hz
0.79
Factor IA / IN
6.5
η (IE3) %
84
A
140 mm
C
245 mm
B
300 mm
H
90 mm
Ø D shaft
24 mm
Ø E
130 mm
Ø F
200 mm
Vse lastnosti

Lastnosti

Ambient temperature
  • -20 °C to +40 °C 
Protection IP
  • IP 55 
Material
  • housing: aluminium 
Design
  • Type B3/B5 
  • removable feet 
Customs tariff number
  • 85015220 
Vse lastnosti

Opis izdelka

Opombe
Caution! Measurement »B« can depending on design slightly vary in length.
Opis
Self-cooling squirrel-cage energy-saving motors.
High efficiency IE3 - IEC60034-30:2009.
Rated voltage 230/400 V 50 Hz, 460 V 60 Hz.
4-pin.
Voltage tolerance ±5 %.

Product variants

5 Results
Prikaz dimenzijske risbe
Oznaka
P 60 Hz (kW)
n 60 Hz (r/min)
P 50 Hz (kW)
n 50 Hz (r/min)
Podrobnosti / Kos
0,86 kW
1.716 r/min
0,75 kW
1.430 r/min
Več informacij
1,3 kW
1.740 r/min
1,1 kW
1.440 r/min
Več informacij
1,75 kW
1.745 r/min
1,5 kW
1.445 r/min
Več informacij
2,55 kW
1.765 r/min
2,2 kW
1.465 r/min
Več informacij
3,45 kW
1.760 r/min
3 kW
1.460 r/min
Več informacij
P 60 Hz = nominal output at 400 V/60 Hz
n 50 Hz = nominal speed at 400 V/50 Hz
n 60 Hz = nominal speed at 400 V/60 Hz
I 50 Hz = nominal current at 400 V/50 Hz
LF 50 Hz = cos phi power factor at 50 Hz
P 50 Hz = nominal output at 400 V/50 Hz
η (IE3) = efficiency to IE3 in % (at full load)
Factor IA / IN = start-up current IA / Nominal current IN

Column selection

P 60 Hz (kW)
n 60 Hz (r/min)
P 50 Hz (kW)
n 50 Hz (r/min)
I 50 Hz (A)
LF 50 Hz
Faktor IA/IN
η (IE3) %
A (mm)
C (mm)
B (mm)
H (mm)
Ø D grede (mm)
Ø E (mm)
Ø F (mm)
P 60 Hz = nominal output at 400 V/60 Hz
n 50 Hz = nominal speed at 400 V/50 Hz
n 60 Hz = nominal speed at 400 V/60 Hz
I 50 Hz = nominal current at 400 V/50 Hz
LF 50 Hz = cos phi power factor at 50 Hz
P 50 Hz = nominal output at 400 V/50 Hz
η (IE3) = efficiency to IE3 in % (at full load)
Factor IA / IN = start-up current IA / Nominal current IN