What are you looking for?

Enter search term

We are sorry!

Unfortunately no results were found.

Christmas / New Year shipping times
Our central warehouses will be closed from 23.12.2024 to 01.01.2025. Incoming orders will not be shipped during this period. If necessary, you are welcome to use our branch network during this time. Customer service will be available as usual.

Please note that our branches may have different opening hours during the holidays. For up-to-date information, we recommend calling ahead or checking the current opening times on Google Maps. Due to technical reasons, we are currently unable to update the opening hours on our website. Link to branch search on Google Maps

Login

Sunteţi client nou?

Înregistraţi-vă şi bucuraţi-vă de multe avantaje:

Verificarea disponibilităţii produsului
Comandare suplimentară rapidă & istoricul comenzilor
Recomandări personale ale produsului
Plată cu factură

Help & Contact

Your direct line to us

If you have any questions about the online store or our products, you can call our customer service at:

Monday - Thursday: 8:00AM - 5:00PM
Friday: 8:00AM - 4:00PM
Except saturdays, sundays and holidays

Or use our FAQ

There you get answers to the most frequently asked questions.

Helping people help themselves
Întrebări frecvente

HK OLM 0.32 210 A

Diaphragm accumulator 0.32L 210bar
Product details for

HK OLM 0.32 210 A

Type
1
Gas volume l
0.32 l
p max.
210 bar
pma : p0
8:1
p max - p min
175 bar
A
140 mm
B
20 mm
F
G 1/2″ -14
SW
32 mm
Ø D
95 mm
Ø G
29 mm
All characteristics

Characteristics

Material
  • type 1: membrane NBR 
  • type 2: membrane ECO 
Application
  • Energy storage 
  • Emergency actuation 
  • Leak oil and volume compensation 
  • Shock absorption and pulsation damping 
  • Suspension of vehicles 
Connections
  • Oil side type A - female thread 
Construction type
  • installation preferably vertical, gas side top 
Temp. range
  • Type 1: -10 °C to +80 °C 
  • Type 2: -40 °C to +80 °C 
Customs tariff number
  • 84798997 
All characteristics

Descrierea produsului

Notes
CE-mark for diaphragm accumulators > 1.0 l gas volume
Working pressure 100 to 350 bar; min. working pressure must be 10% above gas charge pressure
Max. gas filling pressure 130 bar
Description
As liquids are practically incompressible, the compressibility of a gas (in this case nitrogen) is used in hydraulic accumulators to store energy.
A hydraulic accumulator consists of two chambers (liquid side and gas side), which are separated by a flexible, gas-tight element. The liquid side is connected to the hydraulic circuit of the system. When the pressure in the system rises, the accumulator is filled with oil and the gas is compressed. If the pressure drops, the stored pressurised liquid is forced back into the circuit by expansion of the compressed gas.
Ordering information
Pressure accumulators are available uncharged ex-warehouse. Additional costs apply upon customer request for N2-charging.

Product variants

13 Results
Show dimensional drawing
Identifier
Type
Gas volume l (l)
p max. (bar)
pma : p0
Details / items
0.075 l
250 bar
8:1 
Learn more
0.16 l
250 bar
6:1 
Learn more
0.32 l
210 bar
8:1 
Learn more
0.5 l
210 bar
8:1 
Learn more
0.75 l
210 bar
8:1 
Learn more
0.75 l
350 bar
8:1 
Learn more
1 l
210 bar
8:1 
Learn more
1.4 l
140 bar
8:1 
Learn more
1.4 l
210 bar
8:1 
Learn more
2 l
100 bar
8:1 
Learn more
Type 1: Standard
Type 2: low temperature version
p0 = gas charge pressure
pmax - pmin = admissible pressure fluctuation of the accumulator

Shows 10 of 13

Column selection

Type
Gas volume l (l)
p max. (bar)
pma : p0
p max - p min (bar)
A (mm)
B (mm)
F
SW (mm)
Ø D (mm)
Ø G (mm)
Type 1: Standard
Type 2: low temperature version
p0 = gas charge pressure
pmax - pmin = admissible pressure fluctuation of the accumulator