HK DPH 2

Directional control valve NG16
Max. working pressure
P, A, B: max. 350 bar / T: max. 210 bar 
Design
4/3-way valve (without pilot valve) 
pilot operated 
Connection
ISO/Cetop 07 size 16 
Descărcare PDF

Vă rugăm să alegeţi un model

Afişare tabel articole

Caracteristici

Max. working pressure
  • P, A, B: max. 350 bar / T: max. 210 bar 
Design
  • 4/3-way valve (without pilot valve) 
  • pilot operated 
Connection
  • ISO/Cetop 07 size 16 
Flow rate
  • max. 300 l/min (note characteristic curves) 
Mounting
  • 2 pcs. hexagon socket screw M 6 x 40 12.9 + 4 pcs. M 10 x 50 12.9 
  • screw set HK M6 40 and HK M10 50 for 1 basic valve. In vertical stacking applications with intermediate plates, the use of the appropriate longer screws are required. 
Customs tariff number
  • 84812010 
Toate caracteristicile

Descrierea produsului

Indicaţii
The O-rings (NBR 90 Shore A) for the valve connecting surface can be separately ordered as replacement parts using the following item number: 4 pieces OR22.23-2.62N90 and 2 pieces OR10.82-1.78N90
Descriere
These valves are actuated by a solenoid directional valve NG6 in leakage oil-reduced design (type HK DHE...P...) to be installed as a pilot valve.
Control is internal, but conversion to external is possible.
Leakage oil is discharged externally.
The minimum control pressure for correct function is 8 bar.
In the version with control pressure generator, an additional pressure drop is generated which ensures the minimum required control pressure for a correct switching function. The version with control pressure generator must be used if the pressure drop in the valve is below the minimum value of the control pressure.
Indicaţie pentru comandă
Further circuits and versions, volumetric flows and switching power limits are available on request

Product variants

4 Results
Afişare desen la cotă
Denumire
Vrsta
Pokrov
Tip klipa
Izvedba
Detalii / Komad
4/3 
negative (open) 
0 [PB/AT]-[ABPT]-[PA/BT] 
spring return, control pressure generator 
Aflaţi mai mult
4/3 
positive (closed) 
1 [PB/AT]-[A/B/P/T]-[PA/BT] 
spring return 
Aflaţi mai mult
4/3 
positive (closed) 
3 [PB/AT]-[ABT/P]-[PA/BT] 
spring return 
Aflaţi mai mult
4/3 
negative (open) 
4 [PA/BT]-[A/B/PT]-[PB/AT] 
spring return, control pressure generator 
Aflaţi mai mult
Piston type example: [A/B/PT] = [A blocked / B blocked / P+T connected]

Column selection

Vrsta
Pokrov
Tip klipa
Izvedba
Piston type example: [A/B/PT] = [A blocked / B blocked / P+T connected]